Pressure/temperature rating – Flowserve BK 212 User Manual
Page 9

9
Technical Data
Pressure/Temperature Rating
for standard equipment
TMA (admissible temperature) in [°C] for butt-weld ends
to DIN 3239
PMA
Form 1 – R6
Form 2 – R8
(allowable pressure)
DN [mm] (in)
DN [mm] (in)
[bar] [psi]
15 (
1
/
2
")
20*) (
3
/
4
")
25 (1")
15 (
1
/
2
")
25 (1")
105
1523
550
550
550
550
550
121
1755
540
550
550
550
550
123
1784
539
549
550
550
550
150
2175
525
535
536
550
550
180
2610
511
521
523
550
550
211
3060
500
509
511
550
550
225
3263
494
505
506
546
550
250
3625
485
497
499
538
542
275
3988
476
487
490
531
535
300
4350
467
481
484
525
528
∆
PMX (max. differential pressure) 250 bar (3625 psi)
(inlet pressure minus outlet pressure)
Pressure/Temperature Rating
for special design (with special bolts and nuts)
TMA (admissible temperature) in [°C] for butt-weld ends
to DIN 3239
PMA
Form 1 – R6
Form 2 – R8
(allowable pressure)
DN [mm] (in)
DN [mm] (in)
[bar] [psi]
15 (
1
/
2
")
20*) (
3
/
4
")
25 (1")
15 (
1
/
2
")
25 (1")
1
67
0
972
580
580
580
580
580
1
78
1131
571
580
580
580
580
1
80
1160
569
579
580
580
580
110
1595
546
556
557
580
580
137
1987
532
541
542
580
580
144
2088
528
538
539
577
580
162
2350
519
529
530
569
580
180
2610
511
521
523
560
573
200
2900
504
513
515
554
565
225
3263
494
505
506
546
557
250
3625
485
497
499
538
550
275
3988
476
487
490
531
543
300
4350
467
481
484
525
537
*) DN 20 not covered by DIN standards.