beautypg.com

I/o card positions a, b, c & d, Control inputs, Wire mode – BSS Audio BLU Series Install Guide User Manual

Page 11: Bc d

background image

5

I/O Card Positions A, B, C & D

OF FIRE REPLACE ONLY WITH THE

ETHERNET

PRIMARY

SECONDARY

A

1

2

3

4

1

2

3

4

B

C

D

IN

OUT

CAUTION:

TO REDUCE THE RISK
SAME TYPE AND RATING OF FUSE

AVIS:

UTILISER UN FUSIBLE DE

RECHANGE DE MEME TYPE

THIS EQUIPMENT MUST BE EARTHED

MANUFACTURED IN THE USA BY BSS AUDIO

RS232

LOCATE

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

WORD CLOCK

T1.6AH - 250V FUSE

100-240V ~ 50/60Hz, 55W

CobraNet

BLU link

IN

OUT

These connectors provide the balanced connections for the I/O card fitted in the four card slots in a Soundweb

London device� The analogue connections are balanced, on Phoenix/Combicon connectors� A green LED next

to the slot assignment letter A, B, C or D indicates that an Input card is fitted and an amber LED when an output

card is fitted. Digital input cards are indicated with a blue LED and digital outputs cards with a red LED. AEC

input cards are indicated with a white LED� Telephone Hybrid cards are indicated with a yellow LED�

Control Inputs

There are 12 control inputs, also known as ‘General Purpose Inputs’ or

‘GPI’. The control inputs are used to connect contact closures (for control of

binary parameters, such as mutes), resistor ladders (for control of multistate

parameters, such as source selectors) or potentiometers (for control of

continuous parameters, such as volume faders)� There are two common

(ground) connections ‘C’ to the left of the 12 control inputs, and two software-

assignable reference voltage outputs ‘R’ to the right. The control ports have two

modes of operation: 2-wire and 3-wire�

2-Wire Mode

In this mode, the 12 control inputs are internally ‘pulled up’ to +5V DC via

a 4�7kOhm resistor� Therefore, no external voltage source is needed to create

contact closure to ground for switches such as mute buttons or, resistance to

ground (for other multi-state or continuous controls such as Parameter Presets

or faders)�

See the Soundweb London help for a table of resistor values for use with

Parameter Presets or source selectors�

A 47kOhm-log potentiometer connected between a control input and

common will allow parameters to be controlled linearly�

switch

2-wire mode

3600R

1800R

1200R

unconnected

ladder

47kOhm

log

potentiometer

470R

3-Wire Mode

This mode allows the use of linear pots or faders for continuous controls� A

pot would be wired as a potential divider with the top of the track connected

to the reference output R, the wiper to a control input and the bottom of the

track to a common C� High performance pots with track resistance between

10kOhms and 100kOhms are recommended�

10K-100kOhm

linear

potentiometer

switch

1k

1k

1k

ladder

1k

4k7