beautypg.com

Wiring diagram, Service procedures, Continued – Desa GK30 User Manual

Page 16: Installing the new assembly

background image

108954

14

SERVICE PROCEDURES

Continued

CAUTION: Ignition control assembly contains

electrostatic components. Handle the assembly by
the edges of the printed circuit board. Do not touch
any of the quick connect terminals or electronic
components.

Installing the New Assembly

1.

Align the five holes in the assembly with the five printed cir-
cuit board supports in the side cover.

2.

Holding the assembly by the edges of the printed circuit board,
apply downward pressure until all five tabs on the printed cir-
cuit board supports springlock into place. Pull up on assembly
to verify this (see Figure 30).

3.

Connect the nine wire leads to the ignition control assembly as
shown in the wiring diagram in column 2.

Figure 30 - Attaching Circuit Board to Tabs

CAUTION: Double check connections. Connect-

ing ignition control assembly wrong could result in
damage to the ignition control assembly and/or other
components in the heater assembly.

Unacceptable

Acceptable

Unacceptable

Acceptable

WIRING DIAGRAM

(7)

(2)

(1)

(8)

(3)

(4)

(6)

(N)

(5)

1a

1

1b

Power Plug

240 V/50Hz

Ignition Control

Green-Yellow

Green-Yellow

Ignitor

Photocell

White

White

Red

Brown/White

Brown

Blue

Blue

Blue

Blue

ON/Off Switch

Black

Black

Motor

4.

Using the 5/16" nut driver or socket wrench reinstall side cover
to heater. Tighten screws until snug. Do not over torque!

SERVICE PROCEDURES
WIRING DIAGRAM

This manual is related to the following products: