Selecting a monitoring preset, Picture 21 : example of monitoring preset recall, 10 selecting a monitoring preset – Analog Way LIVECORE PLATFORM TPP Current Programmer's Guide User Manual
Page 34: 0mlupd, 1mmloa, 1mlupd

34
PROGRAMMER'S GUIDE FOR v02.00.46
3.10 Selecting a Monitoring preset
3.10.1 Usage
This command sequence selects a Monitoring preset and updates/refreshes the Monitoring output.
3.10.2 Detailed commands sequence
Start the monitoring configuration change : This command prepares the Monitoring for a new
configuration by writing the value 0.
Syntax :
0MLupd
L
F
Load the monitoring preset : This command recalls a Monitoring Preset from Memory.
Syntax :
1MMloa
L
F
Apply changes: This command updates the Monitoring.
Syntax :
1MLupd
L
F
3.10.3 Example
This command recalls Monitoring Preset 3 from memory and updates/refreshes the Monitoring output.
Picture 21 : Example of Monitoring preset recall