beautypg.com

Selecting a monitoring preset, Picture 21 : example of monitoring preset recall, 10 selecting a monitoring preset – Analog Way LIVECORE PLATFORM TPP Current Programmer's Guide User Manual

Page 34: 0mlupd, 1mmloa, 1mlupd

background image

34

PROGRAMMER'S GUIDE FOR v02.00.46

3.10 Selecting a Monitoring preset

3.10.1 Usage

This command sequence selects a Monitoring preset and updates/refreshes the Monitoring output.

3.10.2 Detailed commands sequence

Start the monitoring configuration change : This command prepares the Monitoring for a new
configuration by writing the value 0.

Syntax : ,

0MLupd

L

F

is the device index (0 for Master device, 1 for Slave device).

Load the monitoring preset : This command recalls a Monitoring Preset from Memory.

Syntax : ,,

1MMloa

L

F

is the Monitoring preset memory index (0 to 7).

is the device index (0 for Master device, 1 for Slave device).

Apply changes: This command updates the Monitoring.

Syntax : ,

1MLupd

L

F

is the device index (0 for Master device, 1 for Slave device).

3.10.3 Example

This command recalls Monitoring Preset 3 from memory and updates/refreshes the Monitoring output.

Picture 21 : Example of Monitoring preset recall