3 Wiring and Control
All electrical
work must be carried out by a properly licensed electrician, in compliance with
local electrical standards. Failure to observe this point will void the factory warranty for the Tempest 
Enclosure. 
1
Switch off power to the branch circuit, carefully following lockout and tag-out procedures. Failure to do so 
could cause serious injury or death. 
2
You will need two electrical junction boxes, located within a short distance from the enclosure, one for power, 
one for DMX control. Use outdoor-rated flexible conduit between the box and the enclosure. 
3
AC and control circuits must be wired in separate conduits.
Conduit entry holes
Power and DMX conduit entries
The conduit entry holes accept US ½” conduit fittings, and
international 20-22mm (OD) conduit fittings.
For temporary installations, use a suitable cable and clamp in the
same openings.
AC
Power
DMX 
Control 
Flexible Conduit
120VAC, or
208VAC 
or 230VAC 
Lighting 
Control 
AC Power
DMX Control
Ø 0.875” 
22.2mm 