Line #5
19 April 13:27 hours-Date and time stamp

Line #6
Single Test Result - single test only, no averaging of multiple tests

OR (if multiple tests taken)

Number of Tests in Average, Std. Deviation X.XXX - The data on the next line is the result of X
tests being averaged. The Standard Deviation of the 4 STI-PA values is displayed.

Line #7
STI-PA-0.69 - is actual STI-PA value. Single test or averaged.
CIS-0.84 - Common Intelligibility Scale value. Single test or averaged.
Leq - over-all (broad band) Leq taken during the test. Single test or averaged.

Lines #8 to #15
Octave band data from 8k to 125 Hz.
LEQ-is the LEQ value for that octave.
MF1-STI-PA Modulation Index 1
MF2-STI-PA Modulation Index 2
Status-Shows ? is MF1 or MF2 > 1.3
Level-corrected octave RTA amplitudes