Ivie IE-35 RTA - Real Time Analysis User Manual
Quick start, Starting the ie-35 rta controls
dB/division display
dB/Center display
dB SPL display
Averaging Controls
Use the mechanical
buttons to set
dB/division
Tap the "Display" menu and then
"Set dB Scale" to bring up the
dB/Center, dB division window
Weighting - A,C, Flat
RTA display On/Off
Average display On/Off
Store/Recall Memories
Start/Stop RTA
Pushing the center of the
Joystick performs the same
function as Start/Stop RTA
Max Resolution
240 points
30 - 1/3 Octave
bands
60 - 1/6 Octave
bands
10 - 1 Octave
bands
dB Center UP/Down
(I
n increments set by dB/Div)
Tap to Enter or Display the
Preferred Curve. Use Joystick
to enter values: dB & Frequency
Peak Hold
NR
Freq Detect
Turns On/Off
Weighting applied
to the RTA screen.
Frequency Select
(
Used in memory recall)
SPL Response - Fast,
Slow, Peak, Impulse
Preferred Curve Set/Display
2. Press power button
to turn on IE-35
3. Using the stylus tap on
"Start"
Stylus
Signal Generator
/Earphone output
1. Insert the Axim into the IviePAL
jacket and plug in the IE-33M
microphone
4. Using the stylus tap
on "IE-36"
6. The screen of the last
used function will
appear
7. Tap the "Function"
menu and choose the
desired function
RTA
SPL Monitor
Seat to Seat
Strip Chart
Polarity
Voltmeter
RT60 (Optional)
Oscilloscope
Signal Generator
5. Wait while the program
starts and memories are
loaded
Starting the IE-35
RTA Controls
Once the RTA display is stopped
use the Joystick to select and
read dB levels of individual
frequency bands.
Ivie Technologies, Inc Rev. Nov1, 2005
NC
Quick Start