beautypg.com

3 series connection of 4 decentralised modules, 4 voltage drop, 1 guidelines for various cable types – Pilz PNOZ m EF PDP Link User Manual

Page 17: Series connection of 4 decentralised modules, Voltage drop, Guidelines for various cable types

background image

Commissioning

Operating Manual PNOZ m EF PDP Link
1003019­EN­02

17

6.3

Series connection of 4 decentralised modules

You can connect up to 4 decentralised modules in series to a PNOZmulti link module.

PNOZ m EF PDP Link

6.4

Voltage drop

The max. cable length depends on the voltage drop in the supply voltage cables. The level
of voltage drop is determined by the:

}

Cable resistance on the supply voltage cables

}

Operating current of the modules

}

Load on the modules

To increase the max. cable length, the input voltage can be permanently increased by the
voltage tolerance (see Technical Details).

6.4.1

Guidelines for various cable types

Cable type

Voltage drop per 10 m and per 100 mA

PSS SB BUSCABLE LC

0.1 V

Sensor cable 0.25 mm

2

0.15 V

Sensor cable 0.34 mm

2

0.11 V

Sensor cable 0.5 mm

2

0.07 V