beautypg.com

Directed Electronics PYTHON 480XP User Manual

Page 10

background image

10

©

2002

Directed Electronics, Inc.

H1/10 BROWN (+) Horn Honk Output
This wire supplies a (-) 200 mA output that can be used to honk the vehicle horn. It outputs a single
pulse when locking the doors with the remote, and two pulses when unlocking with the remote. This
wire will also output pulses for 30 seconds when the Panic Mode is activated. If the vehicle has a (+)
horn circuit, an optional relay can be used to interface with the system, as shown below.

H1/11 RED (+)12V constant power input
Before connecting this wire, remove the supplied fuse. Connect to the battery positive terminal or
the constant 12V supply to the ignition switch.

NOTE: Always use a fuse within 12 inches of the point you obtain (+)12V. Do not use the 15A
fuse in the harness for this purpose. This fuse protects the module itself.

H1/12 RED/WHITE (-) 200 mA output
When the system receives the code controlling Channel 2, for longer than 1.5 seconds, the
RED/WHITE wire will supply an output as long as the transmission continues. This is often used
to operate a trunk/hatch release or other relay-driven function. This output can also be programmed
to provide the following types of output: Instant validity, latched, latched-reset with ignition, 30-
second timed, or second unlock output. (See Features Description section of this guide for details.)

IMPORTANT! Never use this wire to drive anything but a relay or a low-current input!
The transistorized output can only supply 200 mA of current. Connecting directly to a
solenoid, motor, or other high-current device will cause it to fail.