SWITCH INDICATION

Low speed air volume

preset switch

High/Low delay time
preset switch

Switch indications
on blower unit

Low speed air volume preset switch positions

Air volume

[CFM]

0

30

40

50

60

70

Factory setting: 50 CFM.

Position "0" : Fan stop.
Position : use for factory test only.

High/Low delay time preset switch positions

Delay Time

[min]

0.5

1

2

3

5

10

20

30

60

Factory setting : 20 minutes.
Position : use for factory test only.

OPERATION

Sensor detectible range (FV-08VKME3 only)

The distance that motion
can be detected is iimited
to 10 feet (3m).
The fieid of view of the

sensor is 90°.
(Room temperature is

25 °C)

Motion

> The low speed is determined by Low speed air volume preset switch.

»The delay time is determined by High/Low delay time preset switch.

»The unit maintains the higher speed for an adjustable duration of 0.5 to 60 minutes, after motion is no

longer detected.

m

LU

>

00

o

1

>

u-

Human

active

a

i

iio 1

Fan active At low

speed

when motion is

detected, fan runs
at the high speed.

Remains running

at high speed until
the delay time has

passed.

m

LU

(/>

>

00

o

I

>

Human

active

i[fe

Fan active At low

speed

When manual
wall switch is on,
fan runs at the

high speed.

When manual wall
switch Is off. Fan

remains running at

the high speed until
the delay time has

passed.