beautypg.com

Kistler-Morse KM Load Stand II User Manual

Page 8

background image

97-1100-01 Rev. H

4

www.kistlermorse.com

technicaL SPeciFicationS

FUNCTIONAL

Excitation Voltage - Operating Range

12 VDC - 30 VDC

Current Draw

15.52 mA (70º F, 21º C)

Power Consumption

186.4 mW (70º F, 21º C) at 12 VDC excitation

UBC Allowed Frame and Bolt Loads

Refer to Table

Ultimate Frame and Bolt Design Strength

Refer to Table

Sensor Functional Integrity

200% of rated load

PERFORMANCE

Rated Output

320 mV or 26.6 mV/V @ 12 V Excitation

No Load Output

± 50 mV

Non-Linearity & Hysteresis

± 0.20% of rated output

Repeatability

± 0.10% of rated output

PHYSICAL

Temperature Range

Operational: -30º to 150º F (-34º to 66º C); Unit remains operational, however, if the
temperature exceeds the compensated range, the unit may not perform to specifications

Storage: -30º to 150º F (-34º to 66º C)

Compensated Std Temperature Range: 0º to 100º F (-18º to 38º C)

Compensated Mid Temperature Range: 50º to 150º F (10º to 66º C)

Humidity

100% Non-condensing

Rating

Designed for outdoor applications

Pedestal

ASTM A53 GR B

Flanges

ASTM A36

Junction Box

ABS with UV additive or 304 Stainless Steel

Resilient Pad

Reinforced Rubber

Finish

Polyester Powder Coat

Sensor

Microcell II

Shipping Weight

Refer to Table