Kistler-Morse KM Load Stand II User Manual
Page 8
97-1100-01 Rev. H
4
www.kistlermorse.com
technicaL SPeciFicationS
FUNCTIONAL
Excitation Voltage - Operating Range
12 VDC - 30 VDC
Current Draw
15.52 mA (70º F, 21º C)
Power Consumption
186.4 mW (70º F, 21º C) at 12 VDC excitation
UBC Allowed Frame and Bolt Loads
Refer to Table
Ultimate Frame and Bolt Design Strength
Refer to Table
Sensor Functional Integrity
200% of rated load
PERFORMANCE
Rated Output
320 mV or 26.6 mV/V @ 12 V Excitation
No Load Output
± 50 mV
Non-Linearity & Hysteresis
± 0.20% of rated output
Repeatability
± 0.10% of rated output
PHYSICAL
Temperature Range
Operational: -30º to 150º F (-34º to 66º C); Unit remains operational, however, if the
temperature exceeds the compensated range, the unit may not perform to specifications
Storage: -30º to 150º F (-34º to 66º C)
Compensated Std Temperature Range: 0º to 100º F (-18º to 38º C)
Compensated Mid Temperature Range: 50º to 150º F (10º to 66º C)
Humidity
100% Non-condensing
Rating
Designed for outdoor applications
Pedestal
ASTM A53 GR B
Flanges
ASTM A36
Junction Box
ABS with UV additive or 304 Stainless Steel
Resilient Pad
Reinforced Rubber
Finish
Polyester Powder Coat
Sensor
Microcell II
Shipping Weight
Refer to Table