Kimber Model 84M User Manual
Page 16
F. Disassembly of the Bolt
NOTE: Only the firing pin assembly can be disassembled from the bolt.
1. Make sure the rifle is unloaded. Lift the bolt handle and close it to cock
the firing pin.
2. With the firing pin in the cocked position, pull the safety into the safe
position (see Fig. A1).
3. Lift up on the bolt handle remove the bolt (see Section C).
4. With your hand, unscrew the cocking piece housing counter clockwise
out of bolt. (see Fig. F1)
5. You now have the firing pin assembly ready for inspection, cleaning and
oiling.
G. Removing Barreled Action from Stock
When taking the barreled action out of the stock, the following procedure
should be carefully followed to avoid damage to stock.
1. Put the Safety in the rear (on) position.
2. Remove Bolt assembly (see Section C).
3. Remove both takedown Screws from trigger guard (see Fig. G1).
4. Carefully lift the barreled action from the stock taking particular care to
protect the wood around the receiver tang area.
5. The Magazine Well can easily be removed from the action for cleaning
(see Fig. G2) by lifting the forward section up slightly then pull entire
Magazine Well out of the action. To re-install carefully slip the rear of the
Magazine Well into the action until bottomed out then push the front
down until seated snugly in the action.
NOTE: The floor plate and trigger guard do not have to be removed in order
to take the barreled action out of the stock. If for some reason they are
removed, be sure to replace them before the barreled action is put back into
the stock.
16
F1
Bolt disassembly
NOTE: Further disassembly of
the bolt is not recommended. If
for any reason you cannot
assemble the bolt together, do
not use force. Send the parts to
Kimber Mfg.