Row-pro down pressure setup, Operator’s manual, Requirements – Great Plains DICKEY-john Down Pressure Control User Manual
Page 3: Setup
OPERATOR’S MANUAL
Row-Pro Down Pressure Control
11001-1572-201008
ROW-PRO DOWN PRESSURE SETUP / 1
ROW-PRO DOWN PRESSURE SETUP
The IntelliAg system monitors and adjusts down pressure to ensure the
same amount of force is applied to each row unit to maintain consistent
seed depth placement. The operator sets the desired down pressure into
the IntelliAg virtual terminal and then sets the spring pressure above the
target down pressure.
NOTE: Row-Pro Down Pressure is a
limited automatic adjustment
that works in conjunction
with the down pressure
springs. It does not
independently control the full
range of down pressure.
Down pressure setup can only be accessed in User Level 2 or Level 3
mode.
REQUIREMENTS
The Down Pressure feature is an option available for use with the IntelliAg
system and requires the following components to operate:
• Down Pressure Module that interfaces with 2 load cells
• A maximum of 3 load cell modules can be connected
• Down pressure module harness
NOTE: The Row-Pro system is only
compatible with Great Plains
planters.
SETUP
Down Pressure setup is configured at the Module Configuration screen.
1. At the Main Work screen, press the Next Page button.
2. Press the Module Cfg button.
3. At the Module Configuration screen, press the DPress Set button.
4. At the Down Pressure Set screen, enter desired constants.
Figure 1
Down Pressure Setup
10258
10261
WSMB-DPLCM
WSMB-DPLCM
3
4
150
150