Banner SI-HG63 Hinge Style Switches User Manual
Hinge wing safety interlock switches
SI-HG80 Series Safety Interlock Switches encapsulated in a load-bearing hinge
• Safety switch is integrated and encapsulated into a load-bearing hinge, providing a
high degree of protection from intentional defeat
• Identical in appearance to non-switching blank hinge (see
on page 6)
• Switch components concealed inside the hinge are protected from mechanical impact,
providing superior performance to actuator-activated safety switches; rated IEC IP67
• Hinge operates to a full 180° range of motion; safety switching point (guard-closed po-
sition) is adjustable over the full 0–180°operating range
• Hinge can support an axial load of 750 N and more than 1,000 N in radial direction
• When properly interfaced or used with an appropriate controller, two SI-HG80D..
switches can achieve safety category 4, per ISO 13849 (EN 954-1)
• Robust zinc die-cast housing is corrosion resistant
• Typical applications include:
• Hinged covers and guards to machines
• Hinged doors and gates in safety fencing systems
• Modular aluminum framing
Inline QD Fitting Right-angle QD Fitting
Model
QD Connection
Contact Configuration
(Closed State)
Contact Configuration
(Open State)
Switching Diagram
SI-HG80DQD
Inline QD Fitting
1
3
2
4
1
3
4
2
1-2
Safety
Operating
Angle
3°
3°
10°
10°
SI-HG80DQDR
Right-angle QD Fitting
Note: Terminal #3 is non-safety.
Switching Diagram Key
Contacts:
Open
Closed
Transition
Important Information Regarding the Use of Safety Switches
In the United States, the functions that Banner safety switches are intended to perform are regulated by the Occupational Safety and
Health Administration (OSHA). Whether or not any particular safety switch installation meets all applicable OSHA requirements depends
upon factors that are beyond the control of Banner Engineering Corp. These factors include the details of how the safety switches are
applied, installed, wired, operated, and maintained.
Banner Engineering Corp. has attempted to provide complete application, installation, operation, and maintenance instructions. This in-
formation is found in the instruction manual packaged with each safety switch. In addition, we suggest that any questions regarding the
use or installation of safety switches be directed to the factory applications department at the telephone numbers or address shown
below.
Hinge Wing Safety Interlock Switches
P/N 046735 Rev. C
2/20/2013
0 046735
3