ROCKLITE AW Manual Rev. B

© 2010-14 Blizzard Lighting, LLC

DMX Mode

Allows the unit to be controlled by any universal DMX controller. If you are unfamiliar with

DMX, please read the DMX Primer on page #15.

1.) The ROCKLITE RGBW is capable of operating with either 4 or 8 DMX chan-

nels. To use the fixture in 4-channel mode, use the

button to select

d001

on the LED Readout.

2.) To operate the fixture in 8-channel mode, use the

button to select

A001

on the LED Readout.

Stand-Alone, Master/Slave, Sound Active Modes:

Allows a single or Master/Slaved units to run factory installed programs at user selectable

speeds.

1.) To set the fixture in Flash/Fade mode, select

FF01-FF99

(Fade Mode,

slowest to fastest) or

CC01-CC99

To confirm, press the button.

2.) To use the fixture in demo mode, select

dEoo

, then press the

button to confirm.

3.) Each fixture is a master by default. To set the fixture as a slave, use the

button to reach

SLAv,

then press the button to confirm.

Sound Acitve Mode:

1.) To use sound active mode, select either

SouD

.

2.) Press the button to confirm.

Manual Mode (Color Preset Mode):

Allows a single unit to display a variety of colors without a DMX controller.

1.) Reach the manual adjustment by using the

button to reach

b001.

Adjust each color by using the , and

buttons to select

r001-r255

,

g001-g255

,

b001-b255

or

u001-

u255

(Amber Segment #1, White Segment #1, White segment #2, and Amber

Segment #2, respectively), and adjusting between 1 (lowest) and 255 (highest)

for each color.

To confirm, press the button.