Fixture Linking (Master/Slave Mode)

1. Connect the (male) 3 pin connector side of the

DMX cable to the output (female) 3 pin connector of

the fi rst fi xture.

2. Connect the end of the cable coming from the

fi rst fi xture which will have a (female) 3 pin connec-

tor to the input connector of the next fi xture con-

sisting of a (male) 3 pin connector. Then, proceed

to connect from the output as stated above to the

input of the following fi xture and so on.

A quick note: Often,

the setup for Master-

Slave and Standalone

operation requires that

the fi rst fi xture in the

chain be initialized for

this purpose via either

settings in the control

panel or DIP-switches.

Secondarily, the fi xtures

that follow may also re-

quire a slave setting.

Check the “Operating Adjustments” section in this manual for com-

plete instructions for this type of setup and confi guration.

Mounting & Rigging
This fi xture may be mounted in any SAFE position provided there is

enough room for ventilation.

It is important never to obstruct the fan or vents pathway. Mount the

fi xture using a suitable “C” or “O” type clamp. The clamp should be

rated to hold at least 10x the fi xture’s weight to ensure structural sta-

bility. Do not mount to surfaces with unknown strength, and ensure

properly “rated” rigging is used when mounting fi xutres overhead.

Adjust the angle of the fi xture by loosening both knobs and tilting the

fi xture. After fi nding the desired position, retighten both knobs.

• When selecting installation location, take into consideration lamp

replacement access (if applicable) and routine maintenance.
• Safety cables MUST ALWAYS be used.
• Never mount in places where the fi xture will be exposed to rain,

high humidity, extreme temperature changes or restricted ventilation.

Page 10

ROCKER PANEL RGBAW Manual Rev. A

Copyright (c) 2010 Blizzard Lighting,

LLC

4. OPERATING ADJUSTMENTS

The Dip Switches

All of the various functions of the ROCKER PANEL™ RGBAW are set up using

the 10-position DIP switch located on the rear of the unit. Using this set of

switches, you can select several different standalone, master/slave and DMX

operating modes. The chart below describes the various operating modes and
their respective DIP switch settings.

Function

DIP 1

DIP 2

DIP 3

DIP 4

DIP 5

DIP 6

DIP 7

DIP 8

DIP 9

DIP 10

All Red

ON

All Green

ON

All Blue

ON

All Amber

ON

All White

ON

Strobes

Slow

Fast

Auto Chase

Slow

Med.

Fast

Hyper

ON

OFF

Sound Active

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

Slave

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

DMX CH. #

1

2

4

8

16

32

64

128

256

ON

The Control Panel LED Display shows the menu items you select from

the menu map on page #11. When a menu function is selected, the

display will show immediately the fi rst available option for the selected

menu function. To select a menu item, press .

Press the

button repeatedly until you reach the desired

menu function. Use the and buttons to navigate the

menu options. Press the button to select the menu function

currently displayed, or to enable a menu option. To return to the previ-

ous option or menu without changing the value, press the