beautypg.com

Read and save these instructions, Warning, Caution – Broan Best EB15 User Manual

Page 2: Specifications, Plan the installation, All installations

background image

2

READ AND SAVE THESE INSTRUCTIONS

WARNING

Refrigeration and Air Conditioning Engi-

neers (ASHRAE), and the local code

authorities.

5. When cutting or drilling into wall, or ceil-

ing, do not damage electrical wiring or

other hidden utilities.

6. Ducted fans must always be vented to

the outdoors.

7. To reduce risk of fire, use only metal

ductwork.

8. This unit must be grounded.

CAUTION

1. For general ventilating use only. Do not

use to exhaust hazardous or explosive

material and vapors.

2. To avoid motor bearing damage and

noisy and/or unbalanced impellers, keep

drywall spray, construction dust, etc. off

power unit.

3. Please read specification label on prod-

uct for further information and require-

ments.

4. Electrical circuit, including speed control,

(if used), must be rated 6 AMPS mini-

mum.

WARNING

TO REDUCE THE RISK OF FIRE, ELEC-
TRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended

by the manufacturer. If you have ques-

tions, contact the manufacturer at the

address or telephone number listed in

the warranty.

2. Before servicing or cleaning unit, switch

power off at service panel and lock the

service disconnecting means to prevent

power from being switched on acciden-

tally. When the service disconnecting

means cannot be locked, securely fas-

ten a prominent warning device, such as

a tag, to the service panel.

3. Installation work and electrical wiring

must be done by a qualified person(s) in

accordance with all applicable codes and

standards, including fire-rated construc-

tion codes and standards.

4. Sufficient air is needed for proper com-

bustion and exhausting of gases through

the flue (chimney) of fuel burning equip-

ment to prevent backdrafting. Follow the

heating equipment manufacturer's

guideline and safety standards such as

those published by the National Fire

Protection Association (NFPA), and the

American Society for Heating,

INSTALLER: Leave This Manual With

The Homeowner.

HOMEOWNER: Use And Care

Information On Page 6.

SPECIFICATIONS

MODEL

VOLTS

AMPS

CFM

DUCT SIZE

EB15

120

3.8

1500

10 " DIA.

1. Locate the blower so the length of the

duct run and number of elbows are kept

to a minimum.

2. Where possible, blower

should be centered be-

tween wall studs or roof

rafters.

3. Avoid pipes, wires, or

other ductwork that may

be running through the

wall.

4. Attach mounting plate to

top of hood.

5. Install 10” dia. ductwork

and 120 VAC house wir-

ing between blower lo-

cation and hood location.

ALL INSTALLATIONS

PLAN THE INSTALLATION

MODEL EB15

EXTERIOR BLOWER

ALL HOOD

CANOPY

10" ROUND

DUCT

SOFFIT

ROUGH-IN

PLATE

21" or 24"

10"

or

18"

MODEL

EB15

EXTERIOR

BLOWER

WALL HOOD

CANOPY

10" ROUND DUCT

SOFFIT

ROUGH-IN

PLATE

21" or 24"

10"

or

18"

10" ROUND ELBOW

TYPICAL
ROOF MOUNTED
INSTALLATION

TYPICAL WALL

MOUNTED

INSTALLATION