3 environmental specifications, 1 temperature, 1 operating (continuous) – Barco LC-5621 User Manual
Page 49: 2 storage, 2 altitude/low pressure, 3 relative humidity (rh), 4 emi/emc, 1 immunity en 61000-4-x, 2 emission, 4 other specifications
Barco - LC-5621 - User manual _______________________________________________________ 49
Technical specifications
9.3
Environmental specifications
9.3.1
Temperature
9.3.1.1
Operating (continuous)
•
High temp.: + 35°C (+95°F)
•
Low temp.: + 5° C (+41°F)
9.3.1.2
Storage
•
High temp.: +55°C (+131°F)
•
Low temp.: -20°C (-4°F)
9.3.2
Altitude/Low pressure
•
Operating nom. 3000 m
•
Storage nom. 3000 m
9.3.3
Relative Humidity (RH)
•
Operating & storage: nom 75% @ 35°C (95°F) non-condensing
9.3.4
EMI/EMC
9.3.4.1
Immunity EN 61000-4-x
•
Unit meets following immunity specifications :
3
EN 61000-4-2 (Level 3): Electrostatic Discharge immunity
3
EN 61000-4-3 (Level 3): Radiated, RF immunity, electromagnetic immu-
nity
3
EN 61000-4-4 (Level 3): EFT-Burst immunity
3
EN 61000-4-5 (Level 3): Surge immunity
3
EN 61000-4-6 (Level 2): RF conducted disturbances
3
EN 61000-4-8: Power frequency magnetic immunity
3
EN 61000-4-11: Mains voltage interruptions and variations
9.3.4.2
Emission
•
Unit meets FCC-A
•
Unit meets EN 55022 Limit A
9.4
Other specifications
9.4.1
MTBF
•
50000 hours
9.4.2
MTTR
•
TBD