beautypg.com

Fter, Sing the, Ifter – Wood’s Powr-Grip P11104DCO User Manual

Page 18: Storing the lifter

background image

Rev 13.0/6-13

16

P1-DCO-DVS: #35112

A

FTER

U

SING THE

L

IFTER

Leave the valve handle in the “RELEASE” position (power off).

CAUTION: Do not set the lifter against any surfaces which could soil or damage the

vacuum pads.

The control handle at the end of the pad channel can be used to support an unloaded lifter when

not suspended from a crane: Make sure the pad channel is oriented vertically with the control
handle at the bottom. Use the hoisting equipment to gently lower the lifter until the control

handle supports the entire weight of the lifter. Make sure the lifter leans securely against an
appropriate support; then detach the hoisting equipment hook from the lift bail.
If the lifter is transported to another location, use the original shipping container and secure the

lifter so as to protect the vacuum pads and all other components from damage while in transit.

Storing the Lifter

Use the covers supplied to keep the vacuum pads clean.

!!-CE-!! In accordance with CE Standard EN 13155, the lifter is designed to rest on relatively

horizontal surfaces without tipping over. To store the lifter in this way, set the lifter with the
pads facing downward on a clean, smooth, flat surface. Then lower the lift bar to a horizontal

orientation and place a support under the lift bail.

Charge the battery completely when placing it in storage and at six-month intervals thereafter

(see MAINTENANCE: B

ATTERY

R

ECHARGE

). After charging the battery, disconnect the electrical

connectors uniting the battery to the battery charger and to the vacuum generating system, in
order to minimize power drainage. Preferred temperatures for storing the battery are 32° to 70°
Fahrenheit [0° to 21° Celsius]. Higher temperatures require the battery to be charged more

frequently. Storage at temperatures above 100° Fahrenheit [38° Celsius] should be avoided.