Specifications – Wood’s Powr-Grip P1HV1102DC User Manual
Page 5

Rev 3.0/7-13
3
P1HV1102DC: #35108
SPECIFICATIONS
Model Number:
P1HV1102DC
Description:
Designed for use with a crane or other hoisting equipment, the P1HV1102DC lifter
employs vacuum to hold a load for lifting, and it provides manual 180° rotation and
manual 90° tilt movements for load manipulation.
Vacuum Pads:
Two 10" [25 cm] nominal diameter, lipped (Model HV11)
1
, standard rubber, with #60
filter screen
Maximum Pad Spread:
24" x 11" [610 mm x 279 mm] (to outer edges)
Load Capacity:
(rated at 16" Hg [-54 kPa] on clean, smooth, nonporous flat surfaces
2
)
Per-Pad:
150 lbs [68 kg]
Maximum:
300 lbs [135 kg]
Lifter Weight:
69 lbs [32 kg]
Power Source:
12 volts DC, 10 amps (with Thomas pump) or 3 amps (with Dynaflo pump)
Battery Capacity:
7 amp-hours
Rotation Capability:
Manual, 180°, with automatic locking at each ¼ revolution (when desired)
Tilt Capability:
Manual, 90°, with automatic locking in vertical position
Vacuum Pump:
Diaphragm type, 1 SCFM [28 liters/minute] nominal airflow
Dual Vacuum System:
Two vacuum system circuits allow the lifter to maintain the vacuum level in one circuit
even if an unexpected vacuum loss occurs in the other one (eg, due to load breakage).
Vacuum Reserve Tanks: Two vacuum reservoirs help prevent immediate vacuum loss in case of power failure
and extend battery life by reducing pump cycles required to maintain vacuum.
Vacuum Gauges:
Two dial gauges indicate current vacuum level in positive inches of Hg and negative
kPa.
Low Vacuum Warning Light: Red light is energized until vacuum level is sufficient to lift maximum load weight
(higher than 16" Hg [-54 kPa]) and whenever vacuum loss causes pump to re-engage.
Low Vacuum Warning Buzzer: Maximum Alarm Volume = 103 dBA at 2 ft [60 cm]. While the lifter is powered
up, an audible alarm warns the operator whenever vacuum is not sufficient for lifting
the maximum load weight.
Options:
See separate instructions about optional features.
Operating Elevation:
Maximum = 6000' [1828 m]
Operating Temperatures: 32° to 104° F [0° to 40° C]
Service Life:
This lifter is designed to have a service life of at least 20,000 lifting cycles, when used
and maintained as intended. Vacuum pads, filter elements and other wear-out items
are excluded; see MAINTENANCE and REPLACEMENT PARTS LIST for more information.
For the D
ISPOSAL OF THE
L
IFTER
after its service life, see INTENDED USE.
ASME Standard BTH-1:
Design Category "B", Service Class "0" (see www.powrgrip.com for more information)
!!-CE-!! Note: This symbol appears in the
INSTRUCTIONS
manual only when requirements of a CE Standard are
different
from requirements of other standards that also apply to this vacuum lifter. CE requirements are
mandatory in geographical areas where CE Standards apply, but may be optional in other locations.
1
Available with optional closed-cell foam rings for applications on rough or textured surfaces.
2
Load Capacity is based on a friction coefficient of 1; see MAINTENANCE: V
ACUUM
P
AD
M
AINTENANCE
: Friction Coefficient for
additional information.