beautypg.com

Specifications – Wood’s Powr-Grip PFHL89DCO User Manual

Page 5

background image

Rev 9.0/7-13

3

PF-DCO-DVS: #35132

SPECIFICATIONS

Model Number:

6 Vacuum Pads

8 Vacuum Pads

Vertical Configuration:

PFV69DCO

--

Horizontal / Small Configuration:

PFHS69DCO

PFHS89DCO

Horizontal / Large Configuration:

PFHL69DCO

PFHL89DCO

Maximum Pad Spread: (to outer edges)

Vertical Configuration:

57¼" x 46¼" [1451 x 1172 mm]

--

Horizontal / Small Configuration:

37¼" x 46¼" [943 x 1172 mm]

39¼" x 47" [994 x 1197 mm]

Horizontal / Large Configuration:

46¼" x 57¼" [1172 x 1451 mm]

39¼" x 59½" [994 x 1513 mm]

Lifter Weight: (for larger configurations)

86 lbs [39 kg]

124 lbs [57 kg]

Load Capacity: (rated at 16" Hg [-54 kPa] on clean, smooth, nonporous flat surfaces

1

)

Per-Pad:

125 lbs [56.5 kg]

125 lbs [57 kg]

Maximum:

700 lbs [320 kg]

1000 lbs [455 kg]

Description:

Designed for use with a crane or other hoisting equipment, PF-9DCO lifters employ vacuum to hold a
load for lifting, and they provide manual 180° rotation and manual 90° tilt movements for load

manipulation.

Power Source:

12 volts DC, 10 amps (with Thomas pump) or 3 amps (with Dynaflo pump)

Battery Capacity:

7 amp-hours

Vacuum Pads:

9" [23 cm] nominal diameter (Model VPFS9), standard rubber, spring-mounted (¼" [7 mm] travel),

with #60 filter screen

Rotation Capability:

Manual, 180°, with automatic locking at each ¼ revolution (when desired)

Tilt Capability:

Manual, 90°, with automatic locking in vertical position

Vacuum Pump:

Diaphragm type, 1 SCFM [28 liters/minute] nominal airflow

Vacuum Reserve Tanks: Vacuum reservoirs help prevent immediate vacuum loss in case of power failure and extend battery

life by reducing pump cycles required to maintain vacuum.

Vacuum Gauges:

Dial gauges indicate current vacuum level in positive inches of Hg and negative kPa.

Low Vacuum Warning Light: Red light is energized until vacuum level is sufficient to lift maximum load weight (higher than

16" Hg [-54 kPa]) and whenever vacuum loss causes pump to re-engage.

Low Vacuum Warning Buzzer: Maximum Alarm Volume = 103 dBA at 2 ft [60 cm]. While the lifter is powered up, an

audible alarm warns the operator whenever vacuum is not sufficient for lifting the maximum load
weight.

Options:

Model EO10DVS - Dual Vacuum System. Two vacuum system circuits allow the lifter to maintain the
vacuum level in one circuit even if an unexpected vacuum loss occurs in the other one (eg, due to

load breakage). See separate instructions about other options.

Operating Elevation:

Maximum = 6000 feet [1828 meters]

Operating Temperatures: 32° to 104° F [0° to 40° C]
Service Life:

This lifter is designed to have a service life of at least 20,000 lifting cycles, when used and

maintained as intended. Vacuum pads, filter elements and other wear-out items are excluded; see
MAINTENANCE and REPLACEMENT PARTS LIST for more information. For the D

ISPOSAL OF THE

L

IFTER

after its service life, see INTENDED USE.

ASME Standard BTH-1:

Design Category "B", Service Class "0" (see www.powrgrip.com for more information)

!!-CE-!! Note: This symbol appears in the

INSTRUCTIONS

manual only when requirements of a CE Standard are

different

from requirements of other standards that also apply to this vacuum lifter. CE requirements are

mandatory in geographical areas where CE Standards apply, but may be optional in other locations.

1

Load Capacity is based on a friction coefficient of 1; see MAINTENANCE: V

ACUUM

P

AD

M

AINTENANCE

: Friction Coefficient for

additional information.

This manual is related to the following products: