beautypg.com

Features, Esr2800, Rear panel – KV2 Audio ESR212 User Manual

Page 8: Features 8

background image

Features

Rear panel

1) MAIN INPUT / TROUGHT OUT
This is the main system input balanced XLR connector with associated Through Signal Output connector for
sending unprocessed signal to other devices in a system.

2) SUB OUT
Balanced XLR output connector, used to connect additional subwoofer. Output is active even when FULL RANGE
switch is ON.

3) FULL RANGE
Switch, selects the amplifier crossover setup, when ON full range signal is reproduced by ESR212 cabinets, when
OFF signal is by frequency band in conjunction with the subwoofer output setup.

4) SUB LEVEL
This is the level control for the External Sub output in the range -6 to +6 dB.

5) MONO
Switch, sets SUB OUT outputs summing SUB OUT outputs channel A and B together.

6) PowerCon Power Connectors
The ESR2800 Amplifier uses two connectors per two channel. Each connector supplies one channel. They accept
standard PowerCon terminated AC Mains cables.

7) Fans
The cooling fans operate continuously while the amplifier is on. An internal temperature sensor increases the
speed of the fans during high temperature conditions. Air enters through the front grille and exits through the
rear. Be sure to allow adequate air flow to the front of the rack in which the ESR2800 Amplifier is mounted.

8) Speaker EP6 Connectors
Accepts a standard EP6 terminated loudspeaker cable for connecting up to a single ESR212 cabinet. We recom-
mend using 2.5mm/core cables.

8

6

5

4

3

1

2

THROUGHT OUT

SUB OUT

SUB OUT

THROUGHT OUT

MAIN

INPUT

MAIN

INPUT

SUB LEVEL

FULL RANGE

MONO

OFF

ON

OFF

ON

AC IN

A

AC IN

B

WWW.KV2AUDIO.COM
DESIGNED BY KV2 AUDIO

MANUFACTURED IN THE EUROPEAN UNION

SERIAL NUMBER

WARNING:

TO ENSURE PROPER OPERATION ALLOW A MINIMUM OF 6 INS.

OF CLEARANCE FROM THIS SURFACE AND ADEQUATE VENTILATION.

TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THIS

PANEL OR ANY ATTACHED COMPONENT. NO OPERATOR SERVICED ABLE

PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. TO REDUCE

THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE

TO RAIN OR MOISTURE.

ESR2800

AVIS: RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR

WARNING: RISK OF ELECTRIC SHOCK DO NOT OPEN

CAUTION

HIGH VOLTAGE: DO NOT REMOVE THIS PANEL

WARNING

7

ESR2800

Features

8