beautypg.com

Instalaciones típicas, Typical installations instalaciones típicas, Install the housing – Broan 683L User Manual

Page 2: Instalación de la cubierta, New construction, Construcción nueva

background image

CONDUCTO

REDONDO DE

4" (10,2 CM)

CUBIERTA

CABLE DE

ALIMENTACIÓN

VIGUETA

"

I

"

ALETAS DE MONTAJE

MATERIAL

DE CIELO RASO

ESTRUCTURA

ADICIONAL

REJILLA

VIGUETA

"

I

"

*

CUBIERTA

CABLE DE

ALIMENTACIÓN

CONDUCTO

REDONDO

DE 4" (10,2 CM)

REJILLA

VIGUETA

O VIGA DE

2x4 DE

CIELO

RASO

ALETAS DE MONTAJE

MATERIAL

DE CIELO RASO

ESTRUCTURA

ADICIONAL

VIGUETA

O VIGA DE

2x4 DE

CIELO

RASO

*

CUBIERTA

VIGUETA

DEL TECHO

ALETAS DE MONTAJE

REJILLA

MATERIAL

DEL TECHO

CABLE

DE ALIMENTACIÓN

CONDUCTO

REDONDO DE

4" (10.2 CM)

ESTRUCTURA

ADICIONAL

*

CUBIERTA

CABLE DE ALIMENTACIÓN

VIGUETA

"

I

"

ALETAS DE

MONTAJE

MATERIAL

DE CIELO RASO

ESTRUCTURA

ADICIONAL

VIGUETA

"

I

"

REJILLA

*

CUBIERTA

VIGUETA O

VIGA DE

2x4 DE

CIELO

RASO

ALETAS DE

MONTAJE

MATERIAL

DE CIELO RASO

CABLE DE ALIMENTACIÓN

ESTRUCTURA

ADICIONAL

REJILLA

VIGUETA O

VIGA DE

2x4 DE

CIELO

RASO

*

CUBIERTA

VEGUETA

DEL

TECHO

ALETAS DE

MONTAJE

REJILLA

MATERIAL

DEL TECHO

CABLE DE ALIMENTACIÓN

ALETA DE

MONTAJE

MATERIAL DEL

TECHO SUSPENDIDO

CABLE

DE ALIMENTACIÓN

CONDUCTO

REDONDO DE

4" (10.2 CM)

CUBIERTA

REJILLA

MOUNTING

TAB

GRILLE

SUSPENDED

CEILING MATERIAL

POWER

CABLE

4" ROUND

DUCT

HOUSING

INSTALACIONES TÍPICAS

CUBIERTA MONTADA

DIRECTAMENTE EN LA VIGUETA

2x6 (o más grande).

Descarga paralela a las viguetas.

CUBIERTA MONTADA EN UNA ESTRUCTURA ADICIONAL

Descarga a 90º de las viguetas.

CUBIERTA MONTADA EN UNA VIGA DE 2x4

Se requiere una estructura adicional para las aletas de

montaje. Descarga paralela a las viguetas.

CUBIERTA MONTADA EN UNA VIGA DE 2x4

Se requiere una estructura adicional para las aletas de

montaje. Descarga a 90º de las viguetas.

CUBIERTA MONTADA EN UNA VIGUETA “I”

Se requiere una estructura adicional para las aletas de

montaje. Descarga paralela a las viguetas.

CUBIERTA MONTADA EN UNA VIGUETA “I”

Se requiere una estructura adicional para las

aletas de montaje. Descarga a 90º de las

viguetas.

* La estructura adicional debe ser un tramo de 2x6 (altura

mínima), de al menos 9 pulgadas (23 cm) de largo.

2

TYPICAL INSTALLATIONS

INSTALACIONES TÍPICAS

SUSPENDED CEILINGS

Housing hung with wires - 3-point mount.

INSTALL THE HOUSING

- PLEASE NOTE -

THE FOLLOWING INSTALLATION ILLUSTRATIONS SHOW
2 X 6 JOISTS. IF YOU HAVE A TRUSS OR “I”-JOIST IN-
STALLATION, MOUNT THE VENTILATOR TO THE ADDI-
TIONAL FRAMING IN THE SAME MANNER. (Additional
framing must be a 2x6 (minimum height), at least 9-inches
long.)

New Construction

INSTALACIÓN DE LA CUBIERTA

TECHOS SUSPENDIDOS

Cubierta montada con cables. Montaje de tres puntos.

- POR FAVOR NOTE -

LAS SIGUIENTES ILUSTRACIONES DE LA INSTALACIÓN
MUESTRAN VIGUETAS DE 2 X 6. SI LA INSTALACIÓN ES
EN UNA VIGA O EN UNA VIGUETA EN “I”, MONTE EL
VENTILADOR EN LA ESTRUCTURA ADICIONAL DE LA
MISMA MANERA. (La estructura adicional debe ser un
tramo de 2x6 (altura mínima), de al menos 9 pulgadas (23
cm) de largo.)

Construcción nueva

1. Choose the location for your fan in the ceiling. For

best possible performance, use the shortest
possible duct run and a minimum number of
elbows.

2. Position mounting

brackets against joist so
that bottom edge of
housing will be flush with
finished ceiling.
Additional positioning
feature for 5/8”, 1”, & 1-
1/4” thick ceiling
material:
Holes in corners of
housing are labeled with various ceiling material
thicknesses. Position housing so bottom edge of
joist is visible through a matched set of holes. The
housing is now in the proper position for that
ceiling material thickness.
Additional positioning feature for 1/2” thick
ceiling material:
Bend two tabs, on side of housing, 90

0

outward. Lift

housing until tabs contact underside of joist.
Mark the keyhole slot on both mounting brackets.

5/8

1

1-1/4

TAB

ALETA

HOLES

OROFICIOS

BOTTOM EDGE OF JOIST

BORDE INFERIOR DE LA VIGUETA

3. Set housing aside and drive

nails partially into joist at the
top of both keyhole marks.

4. Hang housing from nails

and pound nails tight. To
ensure a noise-free mount,
pound another nail through
the top hole of each
mounting tab.

1. Seleccione la ubicación del ventilador con lámpara en el

cielo raso. Para obtener el mejor rendimiento posible,
utilice un tramo de conductos lo más corto posible y un

número mínimo de codos.

2. Coloque las abrazaderas de

montaje contra la vigueta, de
manera que el borde inferior de
la cubierta quede al ras del
cielo raso terminado.

Característica adicional para
la colocación en material de
cielo raso de 5/8” (1.6 cm), 1”
(2.5 cm) y 1 ¼” (3.2 cm):

Los orificios que se encuentran
en las esquinas de la cubierta

3. Coloque la cubierta a un lado e

introduzca parcialmente los
clavos en la vigueta, en la parte
superior de ambas marcas de los
orificios en forma de cerradura.

4. Suspenda la cubierta con los

clavos e introduzca los clavos
completamente. Para asegurar
un montaje sin ruido, coloque
otro clavo en el orificio superior
de cada aleta de montaje.

están marcados con varios espesores del material del
cielo raso. Coloque la cubierta de manera que el borde
inferior de la vigueta sea visible a través del conjunto de
orificios que coinciden. Ahora la cubierta se encuentra
en la posición adecuada para ese espesor del material
del cielo raso.

Característica adicional para la colocación en
material de cielo raso de ½” (1.3 cm):

Doble a 90º y hacia afuera las dos aletas que se
encuentran a los costados de la cubierta. Levante la
cubierta hasta que las aletas entren en contacto con la
cara inferior de la vigueta.

Marque el orificio con forma de cerradura de ambas
abrazaderas de montaje.