Instalaciones típicas, Typical installations instalaciones típicas, Install the housing – Broan 683L User Manual
Page 2: Instalación de la cubierta, New construction, Construcción nueva
CONDUCTO
REDONDO DE
4" (10,2 CM)
CUBIERTA
CABLE DE
ALIMENTACIÓN
VIGUETA
"
I
"
ALETAS DE MONTAJE
MATERIAL
DE CIELO RASO
ESTRUCTURA
ADICIONAL
REJILLA
VIGUETA
"
I
"
*
CUBIERTA
CABLE DE
ALIMENTACIÓN
CONDUCTO
REDONDO
DE 4" (10,2 CM)
REJILLA
VIGUETA
O VIGA DE
2x4 DE
CIELO
RASO
ALETAS DE MONTAJE
MATERIAL
DE CIELO RASO
ESTRUCTURA
ADICIONAL
VIGUETA
O VIGA DE
2x4 DE
CIELO
RASO
*
CUBIERTA
VIGUETA
DEL TECHO
ALETAS DE MONTAJE
REJILLA
MATERIAL
DEL TECHO
CABLE
DE ALIMENTACIÓN
CONDUCTO
REDONDO DE
4" (10.2 CM)
ESTRUCTURA
ADICIONAL
*
CUBIERTA
CABLE DE ALIMENTACIÓN
VIGUETA
"
I
"
ALETAS DE
MONTAJE
MATERIAL
DE CIELO RASO
ESTRUCTURA
ADICIONAL
VIGUETA
"
I
"
REJILLA
*
CUBIERTA
VIGUETA O
VIGA DE
2x4 DE
CIELO
RASO
ALETAS DE
MONTAJE
MATERIAL
DE CIELO RASO
CABLE DE ALIMENTACIÓN
ESTRUCTURA
ADICIONAL
REJILLA
VIGUETA O
VIGA DE
2x4 DE
CIELO
RASO
*
CUBIERTA
VEGUETA
DEL
TECHO
ALETAS DE
MONTAJE
REJILLA
MATERIAL
DEL TECHO
CABLE DE ALIMENTACIÓN
ALETA DE
MONTAJE
MATERIAL DEL
TECHO SUSPENDIDO
CABLE
DE ALIMENTACIÓN
CONDUCTO
REDONDO DE
4" (10.2 CM)
CUBIERTA
REJILLA
MOUNTING
TAB
GRILLE
SUSPENDED
CEILING MATERIAL
POWER
CABLE
4" ROUND
DUCT
HOUSING
INSTALACIONES TÍPICAS
CUBIERTA MONTADA
DIRECTAMENTE EN LA VIGUETA
2x6 (o más grande).
Descarga paralela a las viguetas.
CUBIERTA MONTADA EN UNA ESTRUCTURA ADICIONAL
Descarga a 90º de las viguetas.
CUBIERTA MONTADA EN UNA VIGA DE 2x4
Se requiere una estructura adicional para las aletas de
montaje. Descarga paralela a las viguetas.
CUBIERTA MONTADA EN UNA VIGA DE 2x4
Se requiere una estructura adicional para las aletas de
montaje. Descarga a 90º de las viguetas.
CUBIERTA MONTADA EN UNA VIGUETA “I”
Se requiere una estructura adicional para las aletas de
montaje. Descarga paralela a las viguetas.
CUBIERTA MONTADA EN UNA VIGUETA “I”
Se requiere una estructura adicional para las
aletas de montaje. Descarga a 90º de las
viguetas.
* La estructura adicional debe ser un tramo de 2x6 (altura
mínima), de al menos 9 pulgadas (23 cm) de largo.
2
TYPICAL INSTALLATIONS
INSTALACIONES TÍPICAS
SUSPENDED CEILINGS
Housing hung with wires - 3-point mount.
INSTALL THE HOUSING
- PLEASE NOTE -
THE FOLLOWING INSTALLATION ILLUSTRATIONS SHOW
2 X 6 JOISTS. IF YOU HAVE A TRUSS OR “I”-JOIST IN-
STALLATION, MOUNT THE VENTILATOR TO THE ADDI-
TIONAL FRAMING IN THE SAME MANNER. (Additional
framing must be a 2x6 (minimum height), at least 9-inches
long.)
New Construction
INSTALACIÓN DE LA CUBIERTA
TECHOS SUSPENDIDOS
Cubierta montada con cables. Montaje de tres puntos.
- POR FAVOR NOTE -
LAS SIGUIENTES ILUSTRACIONES DE LA INSTALACIÓN
MUESTRAN VIGUETAS DE 2 X 6. SI LA INSTALACIÓN ES
EN UNA VIGA O EN UNA VIGUETA EN “I”, MONTE EL
VENTILADOR EN LA ESTRUCTURA ADICIONAL DE LA
MISMA MANERA. (La estructura adicional debe ser un
tramo de 2x6 (altura mínima), de al menos 9 pulgadas (23
cm) de largo.)
Construcción nueva
1. Choose the location for your fan in the ceiling. For
best possible performance, use the shortest
possible duct run and a minimum number of
elbows.
2. Position mounting
brackets against joist so
that bottom edge of
housing will be flush with
finished ceiling.
Additional positioning
feature for 5/8”, 1”, & 1-
1/4” thick ceiling
material:
Holes in corners of
housing are labeled with various ceiling material
thicknesses. Position housing so bottom edge of
joist is visible through a matched set of holes. The
housing is now in the proper position for that
ceiling material thickness.
Additional positioning feature for 1/2” thick
ceiling material:
Bend two tabs, on side of housing, 90
0
outward. Lift
housing until tabs contact underside of joist.
Mark the keyhole slot on both mounting brackets.
5/8
1
1-1/4
TAB
ALETA
HOLES
OROFICIOS
BOTTOM EDGE OF JOIST
BORDE INFERIOR DE LA VIGUETA
3. Set housing aside and drive
nails partially into joist at the
top of both keyhole marks.
4. Hang housing from nails
and pound nails tight. To
ensure a noise-free mount,
pound another nail through
the top hole of each
mounting tab.
1. Seleccione la ubicación del ventilador con lámpara en el
cielo raso. Para obtener el mejor rendimiento posible,
utilice un tramo de conductos lo más corto posible y un
número mínimo de codos.
2. Coloque las abrazaderas de
montaje contra la vigueta, de
manera que el borde inferior de
la cubierta quede al ras del
cielo raso terminado.
Característica adicional para
la colocación en material de
cielo raso de 5/8” (1.6 cm), 1”
(2.5 cm) y 1 ¼” (3.2 cm):
Los orificios que se encuentran
en las esquinas de la cubierta
3. Coloque la cubierta a un lado e
introduzca parcialmente los
clavos en la vigueta, en la parte
superior de ambas marcas de los
orificios en forma de cerradura.
4. Suspenda la cubierta con los
clavos e introduzca los clavos
completamente. Para asegurar
un montaje sin ruido, coloque
otro clavo en el orificio superior
de cada aleta de montaje.
están marcados con varios espesores del material del
cielo raso. Coloque la cubierta de manera que el borde
inferior de la vigueta sea visible a través del conjunto de
orificios que coinciden. Ahora la cubierta se encuentra
en la posición adecuada para ese espesor del material
del cielo raso.
Característica adicional para la colocación en
material de cielo raso de ½” (1.3 cm):
Doble a 90º y hacia afuera las dos aletas que se
encuentran a los costados de la cubierta. Levante la
cubierta hasta que las aletas entren en contacto con la
cara inferior de la vigueta.
Marque el orificio con forma de cerradura de ambas
abrazaderas de montaje.