Install the ductwork, Install electrical, Ducted hoods only – Broan E55000 User Manual

Page 8

background image

- 8 -

ROOF CAP

ROUND DUCT

DECORATIVE

FLUE

HOOD

WALL

CAP

ROUND

ELBOW

24” TO 30” ABOVE

COOKING SURFACE

(see “INSTALL

MOUNTING

BRACKETS” section for

mounting restrictions)

INSTALL THE DUCTWORK

DUCTED HOODS ONLY

NOTE: To reduce the risk of fire, use only

metal ductwork.

1. Decide where the ductwork will run

between the hood and the outside.

2. A straight, short duct run will allow the hood

to perform most efficiently.

3. Long duct runs, elbows, and transitions

will reduce the performance of the hood.

Use as few of them as possible. Larger

ducting may be required for best

performance with longer duct runs.

4. Install a roof or wall cap. Connect round

metal ductwork to cap and work back to-

wards hood location. Use duct tape to seal

the joints between ductwork sections.

6”

ADAPTER

FIG. 5

INSTALL ELECTRICAL

DUCTED and NON-DUCTED HOODS

WARNING : Electrical wiring must be

done by a qualified person(s) in
accordance with all applicable codes and
standards. This range hood must be

properly grounded. Turn off electrical

power at service entrance before wiring.
GROUNDING INSTRUCTIONS

This appliance must be grounded. In the

event of an electrical short circuit, grounding

reduces the risk of electric shock by

providing an escape wire for the electric

current. This appliance is equipped with a

cord having a grounding wire with a grounding plug. The plug must be plugged

into an outlet that is properly installed and grounded.

WARNING - Improper grounding can result in a risk of electric shock.

Consult a qualified electrician if the grounding instructions are not completely

understood, or if doubt exists as to whether the appliance is properly grounded.

Do not use an extension cord. If the power supply cord is too short, have a qualified

electrician install an outlet near the appliance.

1. Plan where the hood will be located above the cook top. Refer to the “INSTALL

MOUNTING BRACKET” section for hood mounting height options.

2. Run 2-wire plus ground power cable to a standard 2” x 4” wall outlet box and 3-

blade, 125 volt, 15 Amp grounded receptacle. Fig. 6.

3. Mount the receptacle 17” to 19” above the bottom of the hood.
4. Locate the box and the receptacle within boundary shown and off center of the

ductwork (to allow for power cord plug and flue clearance).

FIG. 6

17”-19”

4”

8”