Emailusername, Ethernetspeed, Eventlog – ATTO Technology 2700C User Manual
Page 40: Eventlogfilter, Exit, Expressfairness, Fcconnmode, Fcdatarate, Of the appendix

vii
ATTO Technology Inc. iPBridge Installation and Operation Manual
EmailUsername
Configures the user name which authenticates the login
to the SMTP Email server. The user name must not be
more than 128 characters. A user name is not required if
the Email server does not require authentication.
set EmailUsername [username]
SaveConfiguration command required
get EmailUsername
EthernetSpeed
Regulates the speed of the iPBridge Ethernet port. If
Auto is enabled, the Ethernet speed is negotiated. When
hard set, 100 speed is half duplex.
Default: auto
set EthernetSpeed [DPn | mp1 | all] [100 | 1000 | auto]
get EthernetSpeed [DPn | mp1 | all]
EventLog
Regulates event logging. When enabled, the unit records
various system events to the event log.
Default: enabled
set EventLog [enabled | disabled]
get EventLog
EventLogFilter
Filters data from specific unit subsystems and levels when
is enabled. The specific entries supported are
platform-dependent. For set commands, the final
parameter indicates whether or not events from the
specified subsystem and level are displayed.
Default: all all all
set EventLogFilter [subsystem | all] [event level | all] [all |
none]
get EventLogFilter [subsystem | all] [level | all ]
Exit
Terminates the current CLI session over Telnet. This
command has no effect if used during a serial CLI
session.
Exit
ExpressFairness
Enables an iSCSI fairness algorithm. which, when a large
number of hosts are connected using iSCSI, prevents one
host from using all available bandwidth and starving
other connections.
Note
Enabling fairness when not needed may
adversely affect performance.
Default: disabled
set ExpressFairness [enabled | disabled]
get ExpressFairness
FCConnMode
Specifies the connection mode the unit uses when
communicating across a Fibre Channel network.
Connection modes:
FC_AL arbitrated loop: loop
Point-to-point: ptp
auto-negotiation, loop preferred: loop-ptp
auto-negotiation, ptp preferred: ptp-loop:
Default: loop
set FCConnMode [fp] [loop | ptp | loop-ptp | ptp-loop]
SaveConfiguration Restart command required
get FCConnMode [fp | all ]
FCDataRate
Specifies the Fibre Channel data rate at which the unit
operates. Choices are 1Gb/sec., 2Gb/sec., 4Gb/sec. or
Auto-negotiate.
Note
The FC data rate displayed in the
toggles between 1Gb, 2Gb and 4Gb on a 4Gb-
capable unit if no connection has been
established.
Default: auto
set FCDataRate [fp | all] [1Gb | 2Gb | 4Gb | auto]
SaveConfiguration Restart command required
get FCDataRate [fp | all]