beautypg.com

Konica Minolta bizhub 754 User Manual

Page 33

background image

bizhub 754/654

2-17

2.3

Preventing Unauthorized Access

2

3

Touch [Prohibited Functions When Authentication Error].

4

Touch [Mode 2].

% Select [Mode 2] when the Enhanced Security Mode is set to [ON]. Selecting [Mode 1] will cancel the

Enhanced Security Mode.

% Set three times or less when the Enhanced Security Mode is set to [ON]. Setting four times or more

will cancel the Enhanced Security Mode.

% To change the check count, touch [+] to increase the count or [-] to decrease it.

5

Touch [Release Time Settings].

6

Touch [C] and, from the keypad, enter the time, after the lapse of which the access lock state of the
Administrator Settings is canceled.

% Touch [Display Keypad] to display the keypad.

% Release Time can be set to any value between 1 min. and 60 min. in 1-min. increments. An input

data error message appears when any value falling outside the range of 1 to 60 min. is set. Enter
the correct Release Time.

% Set 5 min. or more when the Enhanced Security Mode is set to [ON]. Setting 1 to 4 min. will cancel

the Enhanced Security Mode.

7

Touch [OK].