beautypg.com

Installation instructions, Caution – American Electric Lighting American Revolution-247 User Manual

Page 2

background image

American Electric Lighting a division of Acuity Lighting Group, Inc. Granville, OH

DRAWING NO. A72083 REV --

(BACK)

©2008 ACUITY LIGHTING GROUP, INC.

PART NUMBER 057-71-72083

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

POST TOP LUMINAIRE 247 SERIES & TCL cont.

cont.

MOUNTING:

MOUNTING:

NOTE: THIS UNIT WILL ACCEPT POLE TOPS WITH AN

NOTE: THIS UNIT WILL ACCEPT POLE TOPS WITH AN

EXTERIOR DIAMETER BETWEEN 2.375” AND 3“

EXTERIOR DIAMETER BETWEEN 2.375” AND 3“

1. WHEN PLACING THE UNIT ON THE POLE, FEED THE

1. WHEN PLACING THE UNIT ON THE POLE, FEED THE

SUPPLY LEADS THROUGH THE BASE OF THE UNIT.

SUPPLY LEADS THROUGH THE BASE OF THE UNIT.

NOTE: IF UNIT IS PRE-WIRED, FEED THE SUPPLIED

NOTE: IF UNIT IS PRE-WIRED, FEED THE SUPPLIED

PRE-WIRE THROUGH THE POST TOP AND DOWN THE

PRE-WIRE THROUGH THE POST TOP AND DOWN THE

POLE.

POLE.

2. ORIENT THE UNIT SO THAT THE CLOSURE SCREW

2. ORIENT THE UNIT SO THAT THE CLOSURE SCREW

(OR TRIGGER LATCH IF EQUIPPED) ARE TO THE

(OR TRIGGER LATCH IF EQUIPPED) ARE TO THE

STREET SIDE.

STREET SIDE.

3. TIGHTEN THE THREE MOUNTING SET SCREWS.

3. TIGHTEN THE THREE MOUNTING SET SCREWS.

WIRING:

WIRING:

N

NOTE: THIS PROCEDURE IS NOT NECESSARY IF UNIT IS

OTE: THIS PROCEDURE IS NOT NECESSARY IF UNIT IS

SUPPLIED WITH PRE-WIRE.

SUPPLIED WITH PRE-WIRE.

1. OPEN THE UNIT AND REMOVE THE STREET SIDE LENS.

1. OPEN THE UNIT AND REMOVE THE STREET SIDE LENS.

2. LOCATE THE WIRING DIAGRAM ATTACHED TO THE

2. LOCATE THE WIRING DIAGRAM ATTACHED TO THE

INSIDE OF THE HOOD.

INSIDE OF THE HOOD.

3. USING THE WIRING DIAGRAM AS A GUIDE, CONNECT

3. USING THE WIRING DIAGRAM AS A GUIDE, CONNECT

THE POWER SUPPLY LEADS TO THE TERMINAL BLOCK.

THE POWER SUPPLY LEADS TO THE TERMINAL BLOCK.

4. CONNECT THE GREEN OR BARE GROUND SUPPLY WIRE

4. CONNECT THE GREEN OR BARE GROUND SUPPLY WIRE

TO THE CASTING BY HOOKING IT AROUND THE HEAD OF

TO THE CASTING BY HOOKING IT AROUND THE HEAD OF

THE GREEN GROUNDING SCREW, LOCATED BESIDE THE

THE GREEN GROUNDING SCREW, LOCATED BESIDE THE

TERMINAL BLOCK, AND TIGHTENING THE SCREW

TERMINAL BLOCK, AND TIGHTENING THE SCREW

SECURELY.

SECURELY.

5. REINSTALL THE STREET SIDE LENS.

5. REINSTALL THE STREET SIDE LENS.

6. CLOSE THE UNIT.

6. CLOSE THE UNIT.

LAMP INSTALLATION:

LAMP INSTALLATION:

11. OPEN THE UNIT.

. OPEN THE UNIT.

2. SECURELY INSERT LAMP INTO LAMP SOCKET.

2. SECURELY INSERT LAMP INTO LAMP SOCKET.

3. TIGHTEN LAMP WITH ENOUGH TORQUE TO FULLY

3. TIGHTEN LAMP WITH ENOUGH TORQUE TO FULLY

DEPRESS AND LOAD THE CENTER CONTACT OF THE

DEPRESS AND LOAD THE CENTER CONTACT OF THE

SOCKET.

SOCKET.

NOTE: NEMA SPECIFIES TORQUE OF 35 in-lbs.

NOTE: NEMA SPECIFIES TORQUE OF 35 in-lbs.

4. CLOSE THE UNIT.

4. CLOSE THE UNIT.

5. ENERGIZE AND VERIFY OPERATION.

5. ENERGIZE AND VERIFY OPERATION.

PHOTOCONTROL CONT:

PHOTOCONTROL CONT:

1. REMOVE THE CUPOLA CAP BY GRABBING ONE SIDE OF IT AND

1. REMOVE THE CUPOLA CAP BY GRABBING ONE SIDE OF IT AND

LIFTING UP. (SEE FIGURE 1) THE CUPOLA CAP IS VERY RIGID

LIFTING UP. (SEE FIGURE 1) THE CUPOLA CAP IS VERY RIGID

AND TIGHT, DESIGNED SO IT DOESN’T EASILY COME OFF.

AND TIGHT, DESIGNED SO IT DOESN’T EASILY COME OFF.

HOWEVER, IT MAY BE REMOVED BY HAND.

HOWEVER, IT MAY BE REMOVED BY HAND.

2. INSERT THE PHOTOCONTROL INTO THE RECEPTACLE.

2. INSERT THE PHOTOCONTROL INTO THE RECEPTACLE.

3. REATTACH THE CUPOLA CAP. IT SHOULD REATTACH WITH A

3. REATTACH THE CUPOLA CAP. IT SHOULD REATTACH WITH A

VERY AUDIBLE SNAP.

VERY AUDIBLE SNAP.

4. TURN THE PHOTOCONTROL WINDOW TOWARD NORTH BY

4. TURN THE PHOTOCONTROL WINDOW TOWARD NORTH BY

GRABBING THE CUPOLA BASE WITH BOTH HANDS, LIFTING AND

GRABBING THE CUPOLA BASE WITH BOTH HANDS, LIFTING AND

TURNING SIMULTANEOUSLY UNTIL THE CUPOLA WINDOW IS

TURNING SIMULTANEOUSLY UNTIL THE CUPOLA WINDOW IS

FACING NORTH. THE CUPOLA BASE AND THE PHOTOCONTROL

FACING NORTH. THE CUPOLA BASE AND THE PHOTOCONTROL

RECEPTACLE ARE KEYED SO THE PHOTOCONTROL TURNS AS

RECEPTACLE ARE KEYED SO THE PHOTOCONTROL TURNS AS

THE CUPOLA DOES.

THE CUPOLA DOES.

NOTE: FOR ELECTRICAL SAFETY PURPOSES, THE CUPOLA IS

NOTE: FOR ELECTRICAL SAFETY PURPOSES, THE CUPOLA IS

DESIGNED SO THAT IT WILL NOT TURN BEYOND 360 DEGREES.

DESIGNED SO THAT IT WILL NOT TURN BEYOND 360 DEGREES.

DEPENDING ON THE INITIAL ORIENTATION, IT MAY BE NECESS-

DEPENDING ON THE INITIAL ORIENTATION, IT MAY BE NECESS-

ARY TO TURN THE CUPOLA IN THE OTHER DIRECTION IF IT

ARY TO TURN THE CUPOLA IN THE OTHER DIRECTION IF IT

STOPS AND REFUSES TO TURN.

STOPS AND REFUSES TO TURN.

LL ADDER REST INSTALLATION:

ADDER REST INSTALLATION:

NOTE: IT IS DESIGNED TO BREAK-AWAY UNDER SIDE FORCE.

NOTE: IT IS DESIGNED TO BREAK-AWAY UNDER SIDE FORCE.

HOWEVER, IT CAN BE REATTACHED WITH A 1/4-20X3/4 BOLT

HOWEVER, IT CAN BE REATTACHED WITH A 1/4-20X3/4 BOLT

AND NUT AVAILABLE IN THE LADDER REST REPLACEMENT KIT

AND NUT AVAILABLE IN THE LADDER REST REPLACEMENT KIT

(THE KIT ALSO CONTAINS TWO ADDITIONAL LADDER RESTS.)

(THE KIT ALSO CONTAINS TWO ADDITIONAL LADDER RESTS.)

NOTE: THE LADDER REST IS A PRESS FIT DESIGN INTENDED

NOTE: THE LADDER REST IS A PRESS FIT DESIGN INTENDED

FOR INSTALLATION AFTER THE UNIT IS INSTALLED ONTO THE

FOR INSTALLATION AFTER THE UNIT IS INSTALLED ONTO THE

POST TOP.

POST TOP.

1. INSERT THE PIN FEATURE ON THE LADDER REST (SEE FIGURE 3)

1. INSERT THE PIN FEATURE ON THE LADDER REST (SEE FIGURE 3)

INTO THE LADDER REST HOLE LOCATED ON THE LEFT AND

INTO THE LADDER REST HOLE LOCATED ON THE LEFT AND

RIGHT SIDE OF THE LOWER HOUSING JUST ABOVE THE MOUNT

RIGHT SIDE OF THE LOWER HOUSING JUST ABOVE THE MOUNT

SET SCREWS.

SET SCREWS.

2. USING A RUBBER MALLET OR HAMMER, GENTLY KNOCK THE

2. USING A RUBBER MALLET OR HAMMER, GENTLY KNOCK THE

LADDER REST INTO THE HOLE. BE SURE TO KEEP THE LADDER

LADDER REST INTO THE HOLE. BE SURE TO KEEP THE LADDER

REST LINED UP WITH THE HOLE SO THAT THERE IS NO

REST LINED UP WITH THE HOLE SO THAT THERE IS NO

DAMAGE TO THE PIN.

DAMAGE TO THE PIN.

NOTES: IF THE PIN IS DAMAGED BEYOND REPAIR, REMOVE

NOTES: IF THE PIN IS DAMAGED BEYOND REPAIR, REMOVE

IT WITH PLIERS AND REATTACH USING A 1/4-20X3/4 BOLT

IT WITH PLIERS AND REATTACH USING A 1/4-20X3/4 BOLT

AND NUT.

AND NUT.

CAUTION

DO NOT TIGHTEN SET SCREWS

BEYOND 15 ft-lb. TORQUE.

!

PHOTOCONTROL:

PHOTOCONTROL:

NOTE: NO TOOLING IS NECESSARY FOR THE PHOTO-

NOTE: NO TOOLING IS NECESSARY FOR THE PHOTO-

CONTROL INSTALLATION OR ADJUSTMENT.

CONTROL INSTALLATION OR ADJUSTMENT.

- IF NO PHOTOCONTROL OPTION WAS SELECTED, A

- IF NO PHOTOCONTROL OPTION WAS SELECTED, A

CUSTOMER SUPPLIED PHOTOCONTROL WILL NEED

CUSTOMER SUPPLIED PHOTOCONTROL WILL NEED

TO BE INSTALLED. SEE STEP 1 BELOW.

TO BE INSTALLED. SEE STEP 1 BELOW.

- IF “PC” WAS SPECIFIED WHEN ORDERING, THE UNIT WILL

- IF “PC” WAS SPECIFIED WHEN ORDERING, THE UNIT WILL

COME WITH THE PHOTOCONTROL INSTALLED. SEE STEP 4

COME WITH THE PHOTOCONTROL INSTALLED. SEE STEP 4

BELOW.

BELOW.

- IF “NR” WAS SPECIFIED, THE UNIT COMES STANDARD WITH

- IF “NR” WAS SPECIFIED, THE UNIT COMES STANDARD WITH

A SHORTING CAP AND THE STEPS BELOW ARE NOT

A SHORTING CAP AND THE STEPS BELOW ARE NOT

NECESSARY.

NECESSARY.

CAUTION

THE LADDER REST IS FOR COSMETIC

PURPOSES ONLY. IT IS NOT

INTENDED FOR USE AS AN ACTUAL

REST FOR A LADDER.

!

FIGURE 3

FIGURE 3

LADDER REST INSTALLATION

LADDER REST INSTALLATION

PIN

PIN

GENTLY KNOCK HERE

GENTLY KNOCK HERE

FOR INSTALLATION.

FOR INSTALLATION.

IF LAMP IS MARKED

IF LAMP IS MARKED

IT CONTAINS MERCURY.

IT CONTAINS MERCURY.

FOLLOW DISPOSAL LAWS.

FOLLOW DISPOSAL LAWS.

SEE WWW.LAMPRECYCLE.ORG

SEE WWW.LAMPRECYCLE.ORG

Hg