Caution, Warning – Panasonic FV-08VF2 User Manual
Page 5
Power Supply
AC120V 60Hz
Fan unit
Red
Capacitor
White
Black
Green
Earth ground
Junction box
Green
Neutral
Live
Earth
CAUTION:
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. Not for use in cooking area. (Fig. B)
3. This product must be properly grounded.
Floor
Do not install above or
(Cooking area)
inside this area
45
o
45
o
equipment
Cooking
Fig. B
WARNING:
To reduce the risk of fire, electric shock or injury to persons, observe the following;
A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact
the manufacturer.
B. Installation work and electrical wiring must be done by qualified person(s) in accordance with all
applicable codes and standards, including fire-rated construction.
C. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the National Fire Protection Association
(NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers
(ASHRAE) and the local code authorities.
D. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
E. Ducted fans must always be vented to the outdoors.
F. These models are UL listed for tub and shower enclosures.
G. Solid state controls may cause harmonic distortion which can cause motor humming noise. Do not use
this unit with any solid-state control device.
H. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting
means to prevent power from being switched on accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
I. NEVER place a switch where it can be reached from a tub or shower.
J. Not to be installed in a ceiling thermally insulated to a value greater than R40.