Panasonic consumer electronics company, Panasonic canada inc – Panasonic FV-08VF2 User Manual
Page 14
PANASONIC CONSUMER ELECTRONICS COMPANY
One Panasonic Way, 1H-3 Secaucus, NJ 07094
PANASONIC CANADA INC.
5770 Ambler Drive, Mississauga, ON L4W 2T3
Dryer-hood type vent with
backdraft flap(s).
Warning Concerning Removal of Covers.
Fig. 25
Caulk termination to duct.
2-3 ft straight run before elbow.
In attic installation,
caulk box to drywall.
Short piece of flexible duct
helps alignment and absorbs
sound. Clamps plus tape at
all flex joints.
Foil tape tightly covers all metal
duct joints (glue PVC joints).
Insulation.
Loose fill or batt insulation can be placed
directly over the fan housing in the attic.
Panasonic fans and fan/light combination
units do not create excessive heat that is
a common problem with recessed light
fixtures or some competitors' fan/light
combinations. Our efficient, cool-running
motors and our fluorescent bulbs do not
create enough ambient heat to be
subjected to these limitations.
Properly insulate the area around the fan
to minimize building heat loss and gain.
(Fig. 25)
The unit should be serviced by qualified technicians only. No service information is provided for customers.
Your product is designed and manufactured to ensure a minimum of maintenance. However, should your
unit ever require service, a nationwide system of factory service centers and AUTHORIZED INDEPENDENT
SERVICE CENTERS is maintained to support your product's warranty.
(In the U.S.A.,call 1-866-292-7292 to Customer call center.)
14