Vaisala WXT510 User Manual
Page 109

Chapter 8 ____________________________________________ Sensor and Data Message Settings
VAISALA ______________________________________________________________________ 107
Examples (ASCII and NMEA 0183):
Changing the precipitation units to imperial:
0RU,U=I
0RU,U=I
Changing the autosend mode to the tipping bucket mode:
0RU,M=C
0RU,M=C
Making the Rain amount Rc and Rain intensity Ri available both in the
precipitation message and composite data message:
0RU,R=1010000010100000
0RU,R=10100000&10100000
The response after the change:
0R3
0R3,Rc=0.00M,Ri=0.0M
Example (SDI-12, device address 0):
Changing the counter reset mode (resets the precipitation counters):
0XRU,Z=M!0
In SDI-12 mode a separate enquiry (0XRU!) must be given to check the
data content.
where
R, I, U, S,
M, Z
=
The precipitation sensor setting fields, see
Setting
Fields on page 104
.
x
=
Input value for the setting
=
Command terminator in ASCII and NMEA 0183
!
=
Command terminator in SDI-12