beautypg.com

Posey Finger Control Mitts User Manual

Finger control mitts, Application instructions, Rx only

background image

Application

Instructions

DESCRIPTION OF PRODUCT:

A full padded hand mitt with finger separators.

Rx ONLY

Finger Control Mitts

© 2012 Posey Company. All rights reserved.

I9292 REV C 030612

ADDITIONAL SAFETY AND LAUNDERING

INSTRUCTIONS ON OTHER SIDE

2815

2816

Application Instructions

(Repeat steps 1-3 for each mitt):
1. Insert the patient’s hand into the mitt, palm down. Separate

the fingers so each finger fits into its own slot.

2. Wrap the wrist strap around the smallest part of the patient’s

wrist, through the plastic ring, and secure with the hook and

loop fastener.

3. Slide ONE finger (flat) between the device and the inside of

the patient’s wrist to ensure proper fit. The strap must be

snug, but not compromise circulation.

Posey Finger Control Mitts

REF

2815 Finger Control Mitts, Open End

REF

2816 Finger Control Mitts, Closed End

Indications For Use:

• Patients assessed to be at risk of disrupting life-saving treatments (e.g., chronic tube

pulling).

• Patients assessed to be at risk of line pulling, which may prevent monitoring of vital

signs.

• Patients whose picking, pulling, scratching, or peeling exacerbates a skin condition,

causes self-injury, or compromises wound site integrity.

Contraindications:

DO NOT use on a patient who is or becomes highly aggressive, combative, agitated, or

suicidal.

Adverse Reactions:

• Severe emotional, psychological, or physical problems may occur: if the applied device

is uncomfortable; or if it severely limits movement. If symptoms of these problems

ever appear for any reason, get help from a qualified medical authority and find a less

restrictive, product or intervention.

BED SAFETY

• ALWAYS use Hospital Bed Safety

Workgroup (HBSW) (http://www.fda.gov

search keyword “HBSW”) compliant side

rails in the UP position and fill ALL gaps to

reduce the risk of entrapment.

• Use side rail covers and gap protectors to help prevent the

patient’s body from going under, around, through or

between the side rails. A failure to do so may result in

serious injury or death if a patient becomes suspended or

entrapped. Posey offers a full range of side rail pads and/

or gap protectors to cover gaps.

MONITOR PER FACILITY POLICY.

Check to ensure that:

• Mitts are properly secured. If applied too tightly,

circulation will be restricted; if applied too loosely, the

patient may be able to slip his or her limb from the device;

• Mitts are intact, not torn or damaged, and hook and loop

closes securely. DO NOT allow patients to ingest mitt

material;

• The patient cannot use his or her teeth or otherwise

remove the device and inflict self-injury;

• Monitor closely when the patient is out of bed. Patients

who ambulate while wearing this device may be at risk of

injury from a fall.

NEVER use mitts on a patient:

If an IV or wound site could be compromised by the device; or

With a dislocation or fracture on the affected limb.

See the Posey Catalog for other options for such a patient.

ADDITIONAL OR DIFFERENT BODY OR LIMB RESTRAINTS

MAY BE NEEDED (See Posey Catalog):

• To reduce the risk of the patient getting access to the line/

wound/tube site;

• To prevent the patient from flailing or bucking up and

down and causing self-injury.

Posey Company • 5635 Peck Road, Arcadia, CA 91006-0020 USA • www.posey.com

Phone: 1.800.447.6739 or 1.626.443.3143 • Fax: 1.800.767.3933 or 1.626.443.5014

MDSS GmbH

Schiffgraben 41

D-30175 Hannover, Germany

EC REP