Introduction and front panel, Dump, Exit cough start – Symetrix RC-6000 Remote Control User Manual
Page 2: Quick start guide: rc-6000 remote control, Introduction, Mechanical data, Front panel, Rc-6000
2
QUICK START GUIDE: RC-6000 Remote Control
Introduction and Front Panel
6408 216th Street SW
|
Mountlake Terrace, WA 98043 USA
T
+1.425.778.7728
F
+1.425.778.7727
|
www.symetrix.co
Introduction
The AirTools RC-6000 is an accessory remote control
for the 6000 and 6100 Broadcast Audio Delays. The RC-
6000 Remote Control duplicates EXIT, START, COUGH and
DUMP buttons found on the front panel of
the AirTools 6000 and 6100. It also features LED indiction
of the delay’s current status including INACTIVE, ACTIVE,
HALF delay memory built and FULL delay memory built.
Mechanical Data
ITEM
DESCRIPTION
DETAILS
Space Required
WDH: 18.16 cm x 9.78 cm x 3.81 cm / 7.15 in x 3.85 in x 1.5 in.
Depth does not include connector allowance.
Allow at least 1 inch additional clearance for rear panel connec-
tions. Additional depth may be required depending upon your
specific wiring and connections.
Electrical
N/A
Power comes from the 6000 or 6100 via the included cable.
Ventilation
Maximum recommended ambient operating temperature is 30
C / 86 F.
Ventilation should not be impeded by covering the unit with items
such as newspapers, tablecloths, curtains, etc.
Weight
0.24 kg / 0.52 lbs.
FRONT PANEL
ITEM
DESCRIPTION
DETAILS
INACTIVE
Red LED
Indicates that the current delay is fully exited (exactly 0.0 seconds) and the status of the delay is
“DELAY REMOVED”.
ACTIVE
Red LED
Indicates that some amount of delay is currently built and the delay is currently in some mode of opera-
tion.
HALF
Red LED
Indicates that at least half of the currently set amount of delay has been achieved.
FULL
Red LED
Indicates that the full amount of the currently set amount of delay has been achieved.
EXIT
Momentary amber lighted switch
Mirrors the status and function of the EXIT button on the front of the delay. The button flashes to
indicate that the delay is “REDUCING DELAY TIME”.
START
Momentary green lighted switch
Mirrors the status and function of the START button on the front of the delay. The button flashes to
indicate that the delay is “ADDING DELAY TIME”.
COUGH
Momentary white lighted switch
Mirrors the status and function of the COUGH button on the front of the delay. The button lights while
the button is pressed to indicate that the delay is “WAITING FOR RELEASE”.
DUMP
Momentary red lighted switch
Mirrors the status and function of the DUMP button on the front of the delay. The button lights while the
button is pressed.
INACTIVE
ACTIVE
HALF
FULL
RC-6000
REMOTE
CONTROL
EXIT
COUGH
START
DUMP