of 14 and .1 V for an AFR of 15. Other settings, of course, are easily
programmable between the minimum and maximum range specified earlier.

Avoid connecting or disconnecting any of the ports labeled IN or

OUT while the unit is powered ON.

3.2.2

Advanced output programming

The ‘Advanced’ button allows the user to set the analog out update speed
and the voltage output during sensor Warm-up and Error Condition. The
factory defaults of the analog outputs update 1/12 of a second. The default
voltage output is set at 0 volts for both the Warm-up and Error Condition.

When setting the MTX-L to the slower response speed settings the
measured mixture data will be averaged over the response time setting
before being sent via the analog output.

3.2.3

Updating the Firmware

Do not update the firmware if the versions are the same. A

firmware update should only be necessary if there has been a new
release that specifically fixes a problem that you are experiencing with
the controller.

1. Connect the MTX-L to the computer and launch LM Programmer.
2. Once connected, LM Programmer will display the current version of

the firmware that is installed in the MTX-L. Do not update the
firmware if the versions are the same. A firmware update should only
be necessary if there has been a new release.