beautypg.com

Notice, Installation, How to install – LG LT081CNR User Manual

Page 12

background image

12 Room Air Conditioner

Installation

INSTALLATION

• Pick a location which will allow the conditioned air

to blow into the area you want. Good installation
with special attention to the proper position of the
unit will lessen the chance that service will be
needed.

ITEMS IN INSTALLATION HARDWARE

You may not need all parts in the kit. Discard unused
parts

HOW TO INSTALL

Identify the existing wall sleeve before installing
the unit from the listed below.

All wall sleeves used to mount the new Air
Conditioner must be in sound structural condition
and have a rear grille that securely attaches to
sleeve, or rear flange that serves as a stop for the
Air Conditioner.

Remove old air conditioner from existing wall
sleeve.

Clean the interior of an existing sleeve.
(Do not disturb seals.)

Wall sleeve must be securely fastened in wall

before installing the air conditioner. Use the
nails or screws through sleeve into wall, if
needed. Repaint sleeve if needed.

Prepare the wall sleeve for installation of the
unit. If you plan to use your existing wall sleeve,
and it is not LGE, use procedure B or C below.

Install new unit into wall sleeve.

When installation is completed, replacement unit
MUST have a rearward slope as shown. To
achieve 1/4" slope, remove the backing from the
11-13/16" shim strips and attach them as shown
below in Fig. 3. Place the higher portion of shim to
the front of the rib on base of wall sleeve.

NOTICE

1

2

3

4

5

6

1/4"

Wall Sleeve

FRONT

UNIT

SHIM PLACEMENT

UNIT INSTALLATION

1" high

3/4" High

Shim

6"

6"

FIG. 3

We strongly recommend the removal of the
old wall sleeve and the installation of a new
LGE Wall Sleeve.
If you decide to keep the existing wall sleeve,
you have to redirect the louvers at the back of
the wall sleeve illustration. The use of pliers is
recommended. If you DO NOT redirect, you
run the risk of poor performance or product
failure. This is not covered under the terms of
the LGE warranty.

ITEM (inches)

Qty.

Plastic grille

26

3/4

x 16

1/2

1

Vertical insulation strip

15

9/16

x 1

3/8

x 1

3/8

1

Around Insulation Strips

67

1/8

x 1

3/8

x

25/32

1

59

27/32

x 1

3/8

x 1

3/8

1

Horizontal Insulation Strip 23

7/32

x 1

3/8

x 1

3/16

1

Support Block

1

3/4

x 1

3/8

x 4

5/16

2

Baffle

14 x 4

1/2

x

1/8

1

Shim

11

13/16

x 1 x

3/4

2

Trim Frame

2

Washer Screw

4

Nuts(Plastic)

4

Grille Rear

1

Wall Sleeve Dimensions (inches)

Brand

Width

Height

Depth

White-Westinghouse

25-1/2

15-1/4

16, 17-1/2

Frigidaire

or 22

Carrier (52F series)
General Electric

26

15-5/8

16-7/8

/Hotpoint

Whirlpool

25-7/8

16-1/2

17-1/8

or 23

Fedders/Emerson

27

16-3/4

16-3/4

or 19-3/4

LGE

25-7/8 15-17/32 16-23/32

Emerson/Fedders

26-3/4

15-3/4

15

Carrier (51S Series)

25-3/4

16-7/8

18-5/8

Friedrich

27

16-3/4

16-3/4

Procedure

Brand

Depth(inches)

A

LGE

16-23/32

White-Westinghouse
Frigidaire Carrier

16, 17-1/2

(52F series)

or 22

B

General Electric

16-7/8

/Hotpoint
Whirlpool

17-1/8 or 23

Carrier (51S series)

18-5/8

Fedders/Emerson

16-3/4

or 19-3/4

C

Emerson/Fedders

15

Friedrich

16-3/4