Capm-2n carrier frequency pickup module
AW Gear Meters 8809 Industrial Drive, Franksville, WI 53126 web: www.awgearmeters.com
Tel: 262‐884‐9800 Fax: 262‐884‐9810 Email: awinfo@aw‐lake.com
REV. 10/01 CAPM‐2N.DOC
CAPM-2N Carrier Frequency Pickup Module
Description:
The CAPM-2N is used with the HPM series and the TR series of flow meters. The CAPM-2N is a
Carrier Frequency sensor which means there is no permanent magnet in the pickup and any
magnetic drag on the flow meter gears or turbine is avoided. The CAPM-2N requires a supply voltage
between 10 Volt DC to 30 Volt DC. A diode in the supply input prevents damage to the module in
case the polarity of the supply voltage is wrong. The output signal is a square wave. The frequency is
proportional to the flow rate.
The output is a sinking open collector NPT transistor.
Technical Data
:
Supply Voltage
:
10 to 30 Volt DC
Supply Current
:
9 mA @ 15 Volt, Max 18mA
Minimum Signal
:
0.5 Hz
Duty Cycle :
50%
Frequency Output : Flow dependent, up to 2000 Hz
Sinking Capacity: 50 mA Max
Temperature Range:
-60 F to 185 F (-50 C to 85 C)
Connections:
A -
+10 to 30 Volt DC supply voltage
B -
Ground for supply and signals
C -
Frequency signal output
AW Company wire color code:
Supply Voltage:
Red
Ground: Black
Signal: White