Chapter 3 Troubleshooting

1.

Power Input

Verify that is using the right power cord/adapter 48 V

DC

, please don’t use the power

adaptor with DC output voltage higher than 48V, or it will burn this converter down.

2.

Cable

Select the proper UTP cable to construct user network. Please check that is using the

right cable. Use Unshielded Twisted-Pair (UTP) or Shielded Twisted-Pair (STP) cable

for RJ-45 connections: 100 Category 3, 4 or 5 cable for 10 Mbps connections or 100

Category 5 cable for 100 Mbps connections. Also, be sure that the length of any

twisted-pair connection does not exceed 100 meters (328 feet).

3.

Diagnosing LED Indicators

The switch can be easily monitored through panel indicators, which describes common

problems user may encounter and where user can find possible solutions, to assist in

identifying.

If the power indicator does not light up when the power cord is plugged in, user may

have a problem with power cord. Then check for loose power connections, power

losses or surges at power outlet. If user still cannot resolve the problem, contact the

local dealer for assistance.

If the Industrial switch LED indicators are normal and the connected cables are correct

but the packets still cannot transmit, please check your system’s Ethernet devices

configuration or status.