SUMMARY

OPTIONS SELECTION

At the back of the thermostat, there are 3 selection switches to set at

your preferences.

Temperature in °C or °F, time in 12 or 24 hours and Early Start function.

TO SET TIME AND DAY
Press on DAY, HOUR and MIN buttons to adjust time and day.

TO RECORD THE (COMFORT) SETPOINT TEMPERATURE
Select chosen setpoint temperature by using or button. Press on

button (app. 3 seconds) until icon appears on display.

TO RECORD THE (ECONOMY) SETPOINT TEMPERATURE
Select chosen setpoint temperature by using or button.
Press on button (app. 3 seconds) until icon appears on display .

TO RECORD THE (VACATION) SETPOINT TEMPERATURE
To program the Vacation temperature, select the desired degree using the

buttons and press on the and buttons simultaneously

until the icon is displayed (app. 3 seconds).

OPERATING MODES
To select an operating mode, use MODE button.
AUTO:

Runs the program. or shows temperature setting

and can override temporarily your programming up to the

next program.

MAN:

Maintains the selected temperature. or changes

the temperature setting.

Power-up

Set the On/Off switch to On.

When power is applied for the first time, the
display must show the time 00:00, the room
temperature and the Manual mode icon ( ).
Other information might show up on the display if
installation is defective or does not comply with the
instructions.

NOTE: The On/Off switch set to Off will place the

thermostat in sleep mode. Ideal for sum-
mertime.

MODEL TH110A-DP-P

INSTALLATION

PARTS INCLUDED

- One (1) TH110A-DP-P (240 VAC) thermostat

- Two (2) 6-32 screws

- Four (4) solderless connectors (for copper wire)

TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN POWER

PANEL TO AVOID ELECTRICAL SHOCK. Keep air vents of the thermostat clean

and free from obstructions.

u

u

u

u

u

u

NOTE: All cables and connections must conform to the local electrical code.

WARNING: Special CO/ALR solderless connectors must be used when

connecting with aluminum conductors.

920-110-003-00-1-A 1/2

OPERATING MODES

The TH110A-DP-P has two (2) operating modes.

M

ANUAL

( )

This mode allows you to maintain a constant temperature in the room.

1- To activate this mode, press on Mode button to display the icon.
2- Set the desired temperature using the buttons or select the

pre-programmed or or settings.

(To select the setting, press on and simultaneously.)

AUTO

MATIC

( )

This mode executes your own programming.

To activate this mode, press on Mode button to display the icon.

The or icon indicates which temperature setting is used. Also, the icon

of the program number will be shown.

NOTE: The "Problems and Solutions" section at the end of this user's guide will

help you to correct your problems during the installation.
This thermostat has been designed to operate with any installation

which has a RESISTIVE load not exceeding 4000 W (16.67 A) @ 240 VAC

such as electric baseboards, radiant ceilings and floors, electric con

vectors, etc. It is not compatible with a low voltage controller used by

a central heating system.
Electricians or experienced technicians should install the thermostat.
This thermostat is designed to be used with a self-protected heating

system equipped with thermal cut off and circuit breaker.

VAC

B

B

B
B

240

60 HZ

Memory back-up
In the event of a power failure, an internal circuit will maintain the programming

and the time. But only the time could have to be set if power failure is more than

2 hours.

Early Start function
The thermostat is providing a built-in function enabling it to calculate the

optimum time to start the heating system to achieve the desired temperature

setting at the programmed time. This function could start the heating system as

early as 6 hours prior to the programmed time. To enable this function, set the

switch E.S. to “ON” at the back of the thermostat.

Programming the time and day

1- Set the time using the Hour and Min buttons.

2- Set the day using the Day button.

Programming the Comfort, Economy and Vacation settings
The Comfort , Economy and Vacation settings respectively represent

the temperatures that you wish to have during the day , at night or while you

are away at work , or while you are away for an extended period .

PROGRAMMING

AFTER

BEFORE