Pi dbox — model specific installation – Progressive International Electronics EZ Wire DBox User Manual
Page 22
PI DBox
Installation Guide
Version 5.0
January 2012
Page 18
PI DBox — Model Specific Installation
Kraus Electronic Style — KB DBox
Note all warnings in System Installation Warnings section.
KB DBoxes are used with either Kraus or Bennett Electronic Dispensers. Brand selection is made by
simply configuring jumper JP5 to either Kraus or Bennett. Although the same DBox is used in both
applications, in this document we refer to either “Kraus Electronic Style” or Bennett Electronic Style” for
instruction purposes. Note dispenser-specific instructions for use with each dispenser. For overview of
Kraus application see Diagram: Key Components of PI DBox — Kraus/Bennett Style for Kraus
Application following this section.
The following Kraus models must have the minimum version of software noted to work properly with
Progressive equipment:
Micon 100
152 printed circuit board
versions 3.1 & 3.2
252 printed circuit board
version 6.30
463 PLCC processor
version 7.03
Micon 200
version 1.09
Micon 300
version 2.04
Micon 500
all versions
Follow instructions in the installation section of the accompanying product manual before connecting
PI DBox as follows:
1.
Disconnect the Kraus console (if applicable) and connect the Kraus style PI DBox to the PIE
product, using the appropriate cable supplied by PIE. Refer to Diagram: PIE Product to PI
DBox to Kraus Dispenser which follows.
2.
Connect the data communication wires from the Kraus dispenser into the dispenser
connectors on the Kraus Style PI DBox. See Diagram: PIE Product to PI DBox to Kraus
Electronic Dispensers and Diagram: Key Components of PI DBox — Kraus/Bennett Style for
Kraus Application. Also note the layout of the Kraus dispenser head, referring to Diagram:
Kraus Dispenser Head Layout. There are three data communication wires connecting to a
Kraus dispenser. They are labeled as follows:
TTC
Talk to Console/Kraus dispenser transmit data
TTP
Talk to Dispenser/Kraus dispenser receive data
DDC
Data Common / Kraus dispenser ground