120e deadlatch, Folger adam electric locks, Optional features – Southern Folger 120E DEADLATCH User Manual
Page 2: Specifications, Electrical characteristics, Dimensional data
A14
Printed in USA
FA Rev. 0
-1
P.O. Box 2021, San Antonio, TX 78297
s
Ph: 210.533.1231
s
Fx: 210.533.2211
Web: www.SouthernFolger.com
s
Email: [email protected]
Optional Features________
s
Optional solenoid voltage –
230 VAC, 60Hz.
s
Faceplate – US32D finish.
s
Indication/auxiliary switches –
An indication switch monitors the
deadlock lever indicating a
deadlocked latchbolt. The auxiliary
switch monitors the
UROOHUEROW
for
extended or retracted position.
s
Local electric key (LEK) – A unique
function which uses two types of keys
for applications where inmates carry
their own keys, but supervision is
necessary. One key turns in one
direction only and operates the lock
electrically. The supervisory key turns
in both directions to operate the lock
electrically and mechanically. The
electric operation may be cancelled
from a central console or control
point at any time via a three-position
switch.
The Maxi-Mogul
®
Key Cylinder is
uniquely suited for this high
frequency operation, shown by cycle
test of 1,000,000 operations.
LEK not available on any 120E-3
Series Locks.
s
Key Cylinder Extension – When the
lock is keyed on the stop side of the
jamb, an extension eliminates the
need for a special, recessed frame
pocket. Specify E-3 for 3", E-4 for 4"
or E-5 for 5".
The chart at right shows applicability
of above options to all 120E Models.
For complete details, see How to
Specify in this section.
Specifications_________
s
Case and cover – 10 gauge steel.
s
Latchbolt – Investment-cast
stainless steel hardened, 1" throw.
s
Deadlock lever – Stainless
steel, adjustable for door
gap variations.
s
Bolt opening – Does not allow
access to mechanism.
s
Roller bolt – Investment-cast
stainless steel with stainless
steel roller.
s
Operating lever – Stainless steel
to operate with solenoid.
s
Strike – Investment-cast stainless
steel, attached with screws in two
directions.
s
Solenoid – 120 VAC continuous
duty with stainless steel guides;
230VAC optional.
s
Springs – Stainless steel.
Electrical
Characteristics________
s
Solenoid voltages (120 VAC) –
13 amps inrush - .75 amps seated.
s
Solenoid voltages (230 VAC) –
6.6 amps inrush - .38 amps seated.
s
Switches – SPDT, UL Listed,
15 amps @ 125 or 250 VAC.
FOLGER ADAM ELECTRIC LOCKS
Key:
Mogul
Door:
Swinging
Security
Level: Medium/Maximum
120E DEADLATCH
MODEL NO.
OPERATION
LATCHBACK
OPERATIONAL
SWITCHES
INDICATION
SWITCHES
LEK
AVAILABLE
WITH
W/O
HOLDBACK RELOCK INT. DEADLATCH AUX
120E-1-01
Standard (1)
X
X
Yes
120E-1-04
Standard (1a)
X
X
Yes
120E-1-07
Standard (1b)
X
X
X
Yes
120E-2-01
Knob Release (2)
X
X
Yes
120E-2-04
Knob Release (2a)
X
X
Yes
120E-2-07
Knob Release (2b)
X
X
X
Yes
120E-3-01
Key Holdback (3)
X
X
No
120E-3-04
Key Holdback (3a)
X
X
No
120E-3-07
Key Holdback (3b)
X
X
X
No
Dimensional Data________
Note: Dimensions are for information
and planning purposes only, and should