beautypg.com

Southern Folger 120E DEADLATCH User Manual

120e deadlatch, Folger adam electric locks

background image

FA Rev. 02-10

A13

For more information, please call 210.533.1231.

Description______________

Series 120E Deadlatches are pin
tumbler, solenoid-operated locks for
swinging doors. Specify keying as
follows:

121 Keyed case side
122 Keyed cover side
126 Keyed both sides

Applications_____________

Series 120E Deadlatches are suited for
medium or maximum security
application including cell doors, sallyport
or egress doors, corridor or entrance
doors. Sensitive administration areas of
an institution may also warrant 120
Series locks. These jamb-mounted locks
are designed to be part of an electrical
system with remote operation and
monitoring to provide supervisory
personnel with optimum protection and
flexibility.

Operation_______________

Standard (1): Series 120E locks unlock
when the solenoid is energized by a
momentary-contact switch. Once
unlocked, the latchbolt is held
mechanically retracted until the door is
opened. It then extends automatically.

Without latchback (1a) 04 one switch;
05 two switches: Once unlocked, the
latchbolt is held retracted as long as the
solenoid is energized. A maintained
contact switch may be used to keep the
latchbolt retracted for an extended
period of time.

Knob release(2): 120E Deadlatches
may be specified with knob release on
one side, where the knob is always
active. Knob may be mounted on the
case side, or the cover side.

Key holdback (3): When unlocked by
key, the deadlatch remains retracted
until relocked by turning the key in the
opposite direction. Available one side
only. For locks keyed both sides,
available cover side only.

Note: Key cylinders for locks with key holdback
feature must be installed at the factory. This
function is not UL Listed for Fire Doors.

Testing__________________

120E Series Deadlatches and Maxi-
Mogul

®

Key Cylinders have been tested

to 1,000,000 operations.

Standards Compliance___

Series 120E locks are UL Listed as
Burglary-Resistant Mechanisms and Fire
Door Accessories to a three-hour rating.
Maxi-Mogul

®

Key Cylinders meet UL437

requirements.

ASTM F1577 Grade 1 - Impact

Standard Features_______

s

Solenoid voltage – 120 VAC

s

Superior durability – Working parts
of stainless steel afford greater
strength and corrosion-resistance.

s

Standard lock size – All models use
the same size case, cover and
mounting holes for simplified
installation and frame preparation.

s

External two-piece plug connector –
All models install without cover
removal. Simple plug-in connection to
field wiring.

s

External mounting holes – Easy
installation eliminates the need for
cover removal.

s

Standard lock – Mounts behind
frame and does not require a
faceplate.

s

1" throw latchbolt – Offers greater
security. Each bolt is hardened to
resist sawing. When latchbolt is
engaged in strike, bevel is concealed
to prevent picking.

s

Mechanical unlocking by key –
Specify Folger Adam Mogul cylinders,
Maxi-Mogul

®

high security cylinders or

other mogul cylinders.

s

Investment-cast stainless steel
strike – Furnished with four tamper-
resistant screws.

s

Continuous-duty solenoid – For
instant action.

s

Finish – Zinc plated case and cover.

FOLGER ADAM ELECTRIC LOCKS

Key:

Mogul

Door:

Swinging

Security
Level: Medium/Maximum

120E DEADLATCH