beautypg.com

Dc power supply – Securitron M34R_Series User Manual

Page 6

background image

PN# 500-13800

Page 6

Rev. D, 04/11

6.5 Electrical Wiring

The following diagrams, Figures 9, 10, 11 and 12 represent the proper electrical wiring
connections required for the M34R Magnalock Standard, and for the BondSTAT “B”, DPS “D” and

“BD” versions.

_

+

NC

+

C

NO

RED

_

BLK

M34R STANDARD

VERSION

2-WIRE MAGNALOCK

ACCESS

CONTROL

DEVICE

DC

POWER

SUPPLY

120

VAC

INPUT

12/24

VDC

OUTPUT

Figure 9

NC

+

C

NO

NC

RED

_

C

NO

WHT

GRN

ORG

BLK

LOCK

STATUS

REF.

M34R SERIES "B"

BondSTAT VERSION

5-WIRE MAGNALOCK

ACCESS

CONTROL

DEVICE

LOCK

STATUS

_

+

DC

POWER

SUPPLY

120

VAC

INPUT

12/24

VDC

OUTPUT

Figure 10

NC

+

C

NO

REF.

NC

RED

_

C

NO

YEL

BLU

BRN

BLK

M34R SERIES "D"

DPS VERSION

5-WIRE MAGNALOCK

ACCESS

CONTROL

DEVICE

DOOR

STATUS

_

+

DC

POWER

SUPPLY

120

VAC

INPUT

12/24

VDC

OUTPUT

Figure 11

NC

+

C

NO

REF.

REF.

NC

RED

_

C

NO

NO

NC

C

WHT

GRN

ORG

YEL

BLU

BRN

BLK

M34R SERIES "BD"

BondSTAT/DPS VERSION

8-WIRE MAGNALOCK

ACCESS

CONTROL

DEVICE

LOCK

STATUS

DOOR

STATUS

_

+

DC

POWER

SUPPLY

120

VAC

INPUT

12/24

VDC

OUTPUT

Figure 12