Dc power supply – Securitron M34R_Series User Manual
Page 6
PN# 500-13800
Page 6
Rev. D, 04/11
6.5 Electrical Wiring
The following diagrams, Figures 9, 10, 11 and 12 represent the proper electrical wiring
connections required for the M34R Magnalock Standard, and for the BondSTAT “B”, DPS “D” and
“BD” versions.
_
+
NC
+
C
NO
RED
_
BLK
M34R STANDARD
VERSION
2-WIRE MAGNALOCK
ACCESS
CONTROL
DEVICE
DC
POWER
SUPPLY
120
VAC
INPUT
12/24
VDC
OUTPUT
Figure 9
NC
+
C
NO
NC
RED
_
C
NO
WHT
GRN
ORG
BLK
LOCK
STATUS
REF.
M34R SERIES "B"
BondSTAT VERSION
5-WIRE MAGNALOCK
ACCESS
CONTROL
DEVICE
LOCK
STATUS
_
+
DC
POWER
SUPPLY
120
VAC
INPUT
12/24
VDC
OUTPUT
Figure 10
NC
+
C
NO
REF.
NC
RED
_
C
NO
YEL
BLU
BRN
BLK
M34R SERIES "D"
DPS VERSION
5-WIRE MAGNALOCK
ACCESS
CONTROL
DEVICE
DOOR
STATUS
_
+
DC
POWER
SUPPLY
120
VAC
INPUT
12/24
VDC
OUTPUT
Figure 11
NC
+
C
NO
REF.
REF.
NC
RED
_
C
NO
NO
NC
C
WHT
GRN
ORG
YEL
BLU
BRN
BLK
M34R SERIES "BD"
BondSTAT/DPS VERSION
8-WIRE MAGNALOCK
ACCESS
CONTROL
DEVICE
LOCK
STATUS
DOOR
STATUS
_
+
DC
POWER
SUPPLY
120
VAC
INPUT
12/24
VDC
OUTPUT
Figure 12
- ASB_Series (2 pages)
- ASCWB-DM62CL (4 pages)
- CWB_Series (2 pages)
- EASB_Series (4 pages)
- GDB (2 pages)
- HHD (6 pages)
- IK_Series (3 pages)
- M370 (16 pages)
- M38 (L, S and LS with D and T Options) (14 pages)
- M38 T UPGRADE (2 pages)
- M380BD_C_C2_X MAGNALOCK_Series (20 pages)
- M670 (16 pages)
- M680BDCX (16 pages)
- M32 (16 pages)
- Z-32 (2 pages)
- ZA-32 (3 pages)
- UHB (2 pages)
- TJ-38 (7 pages)
- TDK-1 (1 page)
- SWB-03 (2 pages)
- SMLS_SMSS (4 pages)
- SAM2C-24 (1 page)
- SAM2-24 (11 pages)
- SAM (16 pages)
- 32 REPLACEMENT STRIKE (1 page)
- UNL-12 UNLATCH (10 pages)
- STK-1 (2 pages)
- MUNL-12 (11 pages)
- MM15-TS (1 page)
- MM15 Z-Bracket_Series (1 page)
- MM15 (2 pages)
- Blind Nut (1 page)
- FSUNL_Series (2 pages)
- SCL-12 (4 pages)
- MCL-24 (8 pages)
- SWK (2 pages)
- SPK (2 pages)
- SASM KIT STRIKE (1 page)
- GL1 Quick Start (1 page)
- GL1 Install (10 pages)
- FMK-SW (7 pages)
- BPSS-10 (7 pages)
- PB5E (2 pages)
- PB5 (2 pages)