beautypg.com

Sk series, General pump – General Pump SK Owner Manual User Manual

Page 18

background image

GENERAL PUMP

A member of the Interpump Group

SK SERIES

15. TROUBLESHOOTING

The pump does not produce any noise at start-up:

• The pump is not primed and is running dry

• There is no water in the inlet line

• The valves are blocked

• The delivery line is closed and does not allow the air in the pump to be discharged

The pump pulses irregularly (knocking):

• Air suction

• Insufficient feeding

• Bends, elbows, fittings along the suction line obstruct the fluid’s passage

• The inlet filter is dirty or too small

• The booster pump, where provided, supplies insufficient pressure or flow rate

• The pump is not primed due to insufficient head or the delivery line is closed during priming

• The pump is not primed due to valve seizing

• Worn valves

• Worn pressure packings

• Incorrect operation of the pressure adjustment valve

• Transmission problems

The pump does not deliver the rated flow / is noisy:

• Insufficient feeding (see the causes listed above)

• RPM are less than the rated flow

• Excessive amount of water by-passed by the pressure adjustment valve

• Worn valves

• Leakage from the pressure packings

• Cavitation due to:

1) Wrong sizing of the suction hose/

undersized diameters

2) Insufficient flow rate

3) High water temperature

Insufficient pump pressure:

• The nozzle (or has become)too large

• Insufficient RPM

• Leakage from the pressure packings

• Incorrect operation of the pressure adjustment valve

• Worn valves

Overheated pump:

• The pump is overloaded (pressure or RPM exceed the rated values)

• Oil level is too low, or the oil is not of a suitable type, indicated in Chapter 7 (see paragraph 7.4)

• Incorrect alignment of the joint or pulleys

• Excessive inclination of the pump during operation

Pump vibrations or knocking:

• Air suction

• Incorrect operation of the pressure adjustment valve

• Valve malfunction

• Irregular drive transmission motion