Page 17

The following table contains the screw

tightening torque values, to be set by

means of a torque wrench only:

12. SCREW CALIBRATION

13. MAINTENANCE TOOLS

Standard tools are required for the pump

maintenance but to facilitate the mounting

and dismounting operations of some pump

components, you will find the drawings to

make some tools on page 21.

14. PUMP STOPPED FOR LONG TIME

Before starting the pump for the very first

time after a long period from the date of

shipment check for the correct oil level,

check the valves as indicated in chapter

11 and then comply with the starting

procedures indicated in chapter 10. When

a long inactivity is scheduled drain the

entire suction and delivery line and then

run the pump dry only for a few seconds

in order to drain out the water collected

inside the fluid end.

15. PRECAUTIONS AGAINST FREEZING

In the risk of freezing the following

precautions should be taken:

-

After use drain the entire suction and delivery lines

(filter included) by means of discharging devices,

provided and positioned specifically for this purpose

along the lowest point of the lines.

-

Run the pump only for a few seconds in order to

drain the water collected inside the fluid end.

Or when applicable

-

Add a recommended amount of anti-freeze into the

water tank and run the pump until the anti-freeze

works all through the system.

If a pump is frozen or appears frozen ON NO ACCOUNT

SHOULD THE PUMP BE OPERATED until the entire

system has been thawed out.

DESCRIPTION

Ft. Lbs.

N-m

Kgm.

Rear Cover

Screws

7.3

10

1

Plunger Bolts

14.7

20

2

Connecting Rod

Screws

28

38*

4

Valve Plate

Screws

88.5

120**

12

Fluid End Bolts

59

80***

8

Suction Plug

110.6

150

15.2

Delivery Plug

110.6

150

15.2

Auxiliary Plug

29.5

40

4

*

The conrod screws must be tightened as

indicated in point D, page 13.

** The valve plate must be tightened following

the sequence indicated in fig. 24.

*** The fluid end screws must be tightened in 2

stages following the sequence indicated in

fig 24:

First stage: 20 N-m

Second Stage: 80 N-m