beautypg.com

Tsp series “66” servicing instructions, General pump – General Pump 66 Series TSP User Manual

Page 3

background image

GENERAL PUMP

A member of the Interpump Group

TSP Series “66”

Servicing Instructions

Removing/Installing Manifold:

1) Remove fasteners retaining manifold.

2) Separate manifold from crankcase.

Note: it may be necessary to rotate the crankshaft, or tap the manifold

lightly with rawhide mallet to loosen the manifold from crankcase.

Caution: When sliding head from crankcase use caution not to damage

plungers.

3) The seal assemblies may come off with the manifold. At this point

examine the ceramic plungers. Plunger’s surface should be smooth

and free from scoring, pitting, or cracks; if not, replace.

4) Coat each plunger with grease.

5) Align outside pistons in the forward position.

6) Reinstall manifold and torque to specifications per sequence

described below.

TORQUE SEQUENCE FOR TIGHTENING MANIFOLD:

• Install all manifold bolts finger tight.

• Torque to 10 foot pounds in sequence as shown.

• Next torque to specification; again, in sequence.

Replacing ceramic plungers:
1) Remove the plunger retaining bolts with O-ring.
2) Remove the ceramic plunger from piston rod.
3) Inspect plunger bolt O-ring and replace as necessary.
4) Slide new plunger over the piston rod.
5) Apply a drop of removable anaerobic thread sealant to

threads of plunger bolt.

7) Install plunger bolt and torque to specifications.

1

4

6

7

5

3

2

8

Ref 300937 Rev. A

10-13