Mastercool 52251 A_C SYSTEM ANALYZER User Manual
Page 7
7
www.mastercool.com
• USB connection
• 6 AA batteries
Round Vane
Temp. Range/Resolution/Accuracy:
• -20 to 60˚C (-4 to 140˚F)
• 0.1˚C (0.2˚F)
• ±0.6˚C (1.1˚F) (-20 to 50˚C (-4 to 122˚F)),
±1.2˚C (2.2˚F) at other range
Humidity Range/Resolution/Accuracy:
• 0.1% to 99.9% RH
• 0.1% RH
• ±3% RH (at 25˚C (77˚F), 10 to 90% RH), ±5% RH at other range
Windspeed Range/Resolution/Accuracy:
• 0.6 to 32 m/s
• 0.1 m/s
• ±2% of full scale
Antenna Type Meter
Temp. Range/Resolution/Accuracy:
• -20 to 60˚C (-4 to 140˚F)
• 0.1˚C (0.2˚F)
• ±0.6˚C (1.1˚F) (-20 to 50˚C (-4 to 122˚F)),
±1.2˚C (2.2˚F) at other range
Humidity Range/Resolution/Accuracy:
• 0.1% to 99.9% RH
• 0.1% RH
• ±3% RH (at 25˚C (77˚F), 10 to 90% RH), ±5% RH at other range
Windspeed Range/Resolution/Accuracy:
• 0.5 to 25 m/s
• 0.1 m/s
• ±(2% of reading +0.3 m/s)
Pressure Transducer
• Operating Pressure Range: 0-750 psi (0-52 bar)
• 1/4FL Swivel nut connection
• Accuracy: ±0.5, ±1% F.S.
• Operating Temperature: -40 to 100˚C (-40 to 212˚F)
Clamp-on Thermocouple
Temp. Range/Resolution
• -40 to 121˚C (-40 to 250˚F)
• 0.1˚C (0.2˚F)