Magnum Venus Plastech PATRIOT DAILY START UP - Internal Mix User Manual

Daily start up for patriot systems

background image

PATRIOT

MAGNUM VENUS PRODUCTS

DAILY START UP FOR PATRIOT SYSTEMS

Internal Mix System


ACTIVITIES MUST BE DONE IN THE SEQUENCE SHOWN, AND MUST BE TICKED OFF AS

COMPLETED. USE THIS CHECKLIST IN CONJUNCTION WITH THE OPERATING MANUAL FOR THE

PATRIOT UNIT. THIS SEQUENCE FOLLOWS ON FROM

“FIRST TIME START-UP CHECKLIST –

INTERNAL MIX”


ACTIVITY

NO.

ACTIVITY

TICK WHEN
COMPLETED

Priority

Put on Respirator as specified for spray painting, Protective Clothing,
Eye Protection, and PVC Gloves

1

Check all hoses for damage.

2

Check all material supplies and fill or replace as needed.

3

Close the flush tank relief valve

4

Open recirculation valve on Catalyst Manifold

4

Open main inlet air valve on the manifold.

5

Remove the Pivot Pin from the catalyst drive.

6

Manually pump the catalyst pump with the catalyst drive, observe catalyst
returning to the catalyst jug, pump until the stream is air free.

7

Close recirculation valve on Catalyst Manifold.

8

Manually pump the catalyst pump with the Slave Arm drive, bring catalyst
pressure to operating pressure 100

– 200 psi.

9

Check resin pump pressure, if needed slowly turn up the pump air pressure
to the operating pressure, 30

– 50 psi. If a safety over ride valve is installed

press and hold the priming button while adjusting air pressure

10

Replace the Pivot Pin into the catalyst pump drive.

11

Insert the Distribution Ring into the Mix Chamber locating rim.

12

Place mix housing Seal into the Mix Chamber locating rim.

13

Insert the Catalyst Injector and injector seal into the aperture in the
Distribution Ring. The spring goes into the gun block.

14

Place Mix Chamber and Catalyst Injector onto the front of the Pro Gun,
secure it with the 2 screws.

15

Apply a small amount of Red Grease to the threads of the Mix Chamber.

16

Install mixer and nozzle onto the mix chamber.


IF NECESSARY REPEAT THE CHARGING PROCEDURES IN “SET-UP FOR CHARGEABLE PATRIOT
SYSTEMS”

THE UNIT IS NOW READY FOR USE


ABNORMAL CONDITIONS OBSERVED AND CORRECTED

Abnormal Condition

when
corrected




OPERATORS NAME _______________________________________ _DATE: ___________________

SIGN OFF WHEN START UP CHECKS ARE COMPLETED: __________________________________