beautypg.com

Resume dim, Change led brightness (or turn it off) – INSTEON Micro Dimmer - 2442-222 (US), 2442-422 (EU), 2442-522 (AUS/NZ) Manual User Manual

Page 11

background image

Page 11 of 24

2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM

Ramp Rate Presets

“Instant”

0.5 seconds

(factory default)

2 seconds

5 seconds


9) Test by turning off and then back on via the local switch

Light will ramp off and back on at the new local ramp rate

Resume Dim

When resume dim is enabled, each time you turn on Micro module it will go to the previously used dim
level. By default, Micro module will come on at 100% brightness, but to change the desired level, simply
follow the instructions below. The next time you turn Micro module off and on again, it will return to the
last used dim level.

1) Press and hold set button until it beeps

LED will start blinking green

2) Press and hold set button until it beeps a second time

LED will start blinking red

3) Press and hold set button until it beeps a third time

LED will start blinking green

4) Press and hold set button until it beeps a fourth time

LED will start blinking red

5) Slowly tap set button three times

LED will start double-blinking red

6) Press and hold set button until it double-beeps

LED will stop blinking

7) Test by turning off and then back on via the local switch

Light will ramp off and back on to resume dim level.

Change LED Brightness (or turn it off)

Default = 50% brightness level

1) Press and hold set button until it beeps

LED will start blinking green

2) Press and hold set button until it beeps a second time

LED will start blinking red

3) Press and hold set button until it beeps a third time

LED will start blinking green

4) Tap set button once

LED will start double-blinking green

5) Press and hold set button until it beeps

LED will turn green (at brightness of connected load)

6) Press and hold Micro module on/off buttons to brighten or dim LED to desired brightness
7) Tap set button

Micro Module will double-beep and return to ready mode