PREVENTIVE MAINTENANCE


Regular preventive maintenance will help ensure
longer pump life and more reliable operation. It is
recommended that pumps in intermittent operation
be inspected twice a year and pumps in continuous
operation be inspected every 1,000 hours. The
following is a listing of required inspection and
maintenance items.

If any of the problems described in the
following list exists stop operating the pump to
avoid damage or personal injury.

1. CABLE ENTRY

Make sure that the cable entry flange and strain
relief clamp are tight. If the cable entry is showing
signs of leakage remove cable from entry, remove
grommet, cut a piece of cable off so that the
grommet seats on a new portion of the cable,
replace grommet, and reinstall cable assembly, into
the top of the motor.
Note: Explosion Proof cables are sealed with a
Factory Mutual Approved potting compound.
Please consult factory for instruction.

2. CABLES

Inspect the cable for cuts, scrapes or sharp bends.
If the outer jacket is damaged, replace the cable.
Do not attempt splices within wet wells.

3. MOTOR INSULATION RESISTANCE

Megger the insulation between the phases and
between any phase and ground. Resistance
values should be greater than 1 M ohm. If
abnormal readings are obtained contact authorized
service center immediately.

4. EXTERNAL PARTS ON PUMP

Make sure that all screws, bolts and nuts are tight.
Check the condition of pump lifting eyes and
replace if damaged or worn, Replace any external
part that appears worn or damaged.

5. SEAL CHAMBER OIL
Caution seal chamber may be
pressurized

Check the condition of the oil to see if any water
leakage has occurred. Lay the pump on its side
with the plug facing upward and remove the oil fill
plug. Drain the oil from the seal chamber into a
transparent container. Check for impurities and
emulsification (Oil is cream-like). If water intrusion
has occurred check lower mechanical seal and
replace if necessary. Refill seal chamber with fresh
oil. Refer to technical details section for type and
quantity of oil.


6. IMPELLER

Periodically inspect impeller by turning pump on its
side, remove suction strainer nuts and strainer to
expose impeller and relocate position of adjusting
plate (suction cover) as needed. Replace the
impeller if it is damaged or severely worn.

7. PROFILE SEAL

When pump is removed for any service, carefully
inspect the profile seal for signs of damage or
improper sealing. Be sure the contact patch is fully
around the seal face.

SPARE PARTS

In order to obtain spare parts identify the required
parts by contacting authorized HOMA PUMP
TECHNOLOGY representative with the parts
required and the pump serial number. Authentic
Homa Pump Technology parts shall be used to
maintain warranty.
Note: Explosion Proof pumps must be identified as
such, and the pump serial number must be
referenced for proper parts identification.


RECOMMENDED TOOLS AND
SUPPLIES

In addition to ordinary, standard tools and lifting
devices, ensure that complete set of metric Allen
wrenches, dead blow hammer, impeller puller,
Loctite 242 (Blue), petroleum jelly and anti- seize
compound are on hand.