Installation/ assembly, Hydraulic connection – KOSPEL OSV Slim User Manual
Page 19
19
PL;DE;FR;GB;RU-017B_f.449
Installation/ Assembly
•
The heater is to be mounted in
the vertical position.
•
The C distance over the heater
must be observed in order to per-
form maintenance and to exchange
the magnesium anode without tak-
ing the heater off the wall.
•
After the appliance has been fixed
on the wall, it has to be connected
to the water mains. After filling the
appliance entirely with water and
venting (see start-up section),
connect the heater to the electric
mains. Warranty is void if the
installation is not carried out in
accordance with the instructions.
•
In order to situate the appliance in
a correct place, one should take
into account that an emergency
leak from the tank will not cause
flooding of the room.
Hydraulic connection
The heater is a pressure appliance and it is adjusted mains which pressure should
not exceed 0.6MPa. If the pressure is higher than 0.6MPa, a pressure reducing valve
is to be installed before the safety valve.
A small leak from the safety valve through the outlet pipe may occur. It is a normal
operating state of the appliance. The outlet of the pipe has to remain opened. Do not
clog it, as a clogged outlet may cause a break down of the heater.
The safety valve and the outlet pipe must not be exposed to frost.
Please follow the connection instructions below.
•
To the inlet fitting of cold water install:
-
T – connection,
-
safety valve, making sure that the direction of the water flow is accordant with
the arrow on the casing of the safety valve,
-
drain valve according to the schematic diagram.
A draining valve allows for emptying the tank.
There must never be a cut-off valve
between the safety valve and the tank.
5
GB