Xhr series : product specifications – Atec Xantrex-XHR Series User Manual
Page 4

www.ProgrammablePower.com
XHR Series : Product Specifications
XHR 1 kW Internal Interface Specifications with RS-232 or GPIB Interface Installed
1, 8
Model
Program Accuracy
Readback Accuracy
Voltage
(mV)
Current
(mA)
OVP
(mV)
Voltage
Current
XHR 7.5-130
10 +0.12%
900 +0.1%
80
30 +0.12%
900 +0.1%
XHR 20-50
50 +0.12%
750 +0.1%
200
60 +0.12%
750 +0.1%
XHR 33-33
75 +0.12%
500 +0.1%
330
75 +0.12%
500 +0.1%
XHR 40-25
75 +0.3%
350 +0.15%
400
75 +0.3%
350 +0.1%
XHR 60-18
150 +0.25%
250 +0.1%
600
150 +0.25%
250 +0.1%
XHR 100-10
150 +0.35%
140 +0.15%
800
150 +0.35%
140 +0.15%
XHR 150-7
225 +0.35%
120 +0.1%
1500
225 +0.35%
120 +0.1%
XHR 300-3.5
225 +0.35%
80 +0.1%
3000
225 +0.35%
80 +0.1%
XHR 600-1.7
250 +0.35%
80 +0.1%
6000
300 +0.35%
80 +0.1%
Model
Temperature Coefficient
5
Maximum Remote
Sense
Line Drop Compensation
6
OVP Adjustment
Range
(5%to 110% of Vmax)
Efficiency
7
Voltage
(0.02% of Vmax/°C)
Current
(0.03% of Imax/°C)
XHR 7.5-130
1.5 mV
39 mA
3 V / line
0.375-8.25 V
81%
XHR 20-50
4 mV
15 mA
5 V / line
1-22 V
83%
XHR 33-33
6.6 mV
9.9 mA
5 V / line
1.65-36.3 V
83%
XHR 40-25
8 mV
7.5 mA
5 V / line
2-44 V
83%
XHR 60-18
12 mV
5.4 mA
5 V / line
3-66 V
84%
XHR 100-10
20 mV
3 mA
5 V / line
5-110 V
84%
XHR 150-7
30 mV
2.1 mA
5 V / line
7.5-165 V
85%
XHR 300-3.5
60 mV
1.1 mA
5 V / line
15-330 V
85%
XHR 600-1.7
120 mV
0.48 mA
5 V / line
30-660 V
85%
Specifications subject to change without notice.
1. Specifications indicate typical performance at 25°C ± 5°C, nominal line input of 120 Vac.
5. Change in output per °C change in ambient temperature, with constant line and load.
6. Line drop is subtracted from total voltage available at supply output.
7. Typical efficiency at 115 Vac input and rated output power.
8. Apply accuracy specifications according to the following voltage program accuracy example:
Set a model 20-50 power supply to 10 V. The expected result will be within the range of
10 V ± 75 mV ± 0.12% of the set voltage of 10 V.
126